Lutron YK-2001PHA – Water Quality Meter (pH/ORP/DO/CD/TDS/Salt)

Availability:

Stok 5


The YK-2001PHA Multi-Parameter Water Quality Meter offers accurate and reliable measurements for various parameters, making it an essential tool for applications in water conditioning, aquariums, food processing, and more.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

Rp2.031.300,0

Stok 5

Bagikan:

pH/ORP, DO, CD/TDS, SALT METER
Model: YK-2001PHA

OVERVIEW
The YK-2001PHA Multi-Parameter Water Quality Meter offers accurate and reliable measurements for various parameters, making it an essential tool for applications in water conditioning, aquariums, food processing, and more.

FEATURES:
◆ pH : 0 to 14.00 pH, ORP : ± 1999 mV.
◆ Conductivity : 200 uS/2 mS/20 mS/200 mS.
◆ Dissolved oxygen : 0 to 20.0 mg/L.
◆ Salt : 0 to 12 % salt ( % weight ).
◆ Optional pH, ORP, CD/TDS/Salt, Dissolved Oxygen and ATC Probe
◆ Wide applications: water conditioning, aquariums, beverage, fish hatcheries, food processing, photography, laboratory, paper industry, plating industry, quality control, school & college, water conditioning.
◆ LCD with green light backlight, easy reading.
◆ Can default auto power off or manual power off.
◆ Data hold, record max. and min. reading
◆ Microcomputer circuit, high accuracy.

EACH UNIT INCLUDES WITH:
◆ Instruction manual
◆ Conductivity/TDS/Salt probe, CDPB-03

OPTIONAL ACCESSORIES:
◆ pH electrode, PE-03
◆ ATC Temp. probe, TP-07
◆ Dissolved Oxygen probe, OXPB-11
◆ ORP Electrode, ORP-14
◆ Conductivity standard solution, CD-14
◆ USB cable, USB-01
◆ RS232 cable, UPCB-02
◆ Data Acquisition software, SW-U801-WIN

Berat 0,5 kg

GENERAL SPECIFICATIONS

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).

Measurement Function

pH/ORP
Conductivity/TDS(Total Dissolved Solids) Dissolved Oxygen
Salt

Advanced setting

* Auto power OFF management
* Set beep Sound ON/OFF *Settemperatureunitto °Cor°F
* Set DO salt% compensation value
* Set DO height ( meter ) compensation value * Set CD temperature compensation factor

* Set CD to TDS or TDS to CD, CD only
* Set pH manual Temp. compensation value

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Sampling Time of Display

Approx. 1 second.

Data Output

RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.

* Connect the optional USB cable USB-01 will get the USB plug.

Operating Temperature

0 to 50 °C.

Operating Humidity

Less than 85% R.H.

Power Supply

* Alkaline or heavy duty DC 9V ( 006 P ) battery or equivalent.

* DC 9V adapter input. ( AC/DC power adapter is optional ).

Power Current

Normal operation ( LCD Backlight is OFF) : Approx. DC 14 mA.
* If LCD backlight on, the power

consumption will increase approx. 12 mA.

Weight

489 g/1.08 LB.

Dimension

177 x 68 x 45 mm (7.0 x 2.7x 1.9 inch)

Accessories Included

* Instruction manual……………………………..1 PC * Conductivity/TDS/Salt probe, CDPB-03……1 PC

Optional Accessories

* Hard carrying case, CA-06.

* pH electrode………………….. PE-03, PE-11, PE-01, PE06HD PE-04HD, PE-03K7

* ATC probe ( Automatic Temperature Probe )…………………………………..TP-07

* pH 7 buffer solution…………………. pH-07 * pH 4 buffer solution…………………..pH-04

  • *  Pt type Conductivity/TDS probe,
    Salt probe……………………………….CDPB-04
  • *  1.413 mS Conductivity Standard Solution………………………………….CD-14
  • *  Oxygen probe………………………….OXPB-11
  • *  Spare Probe head with DiapHragm set

…………………………………………….OXHD-04 * Probe-filling Electrolyte………………OXEL-03 * ORP Electrode………………………….ORP-14 AC to DC 9V adapter.

USB cable, USB-01.

RS232 cable, UPCB-02.

Data Acquisition software,SW-U801-WIN. Excel Data Acquisition software,SW-E802

ELECTRICAL SPECIFICATIONS (23± 5 °C)

1. pH/mV

pH Electrode

Optional,
Any pH electrode with BNC connector.

Measurement

pH

0 to 14 pH

mV (ORP)

-1999 mV to 1999 mV

Input Impedance

10^12 ohm

Temperature Compensation for pH measurement

Manual

0 to 100 °C, be adjusted by push button on front panel.

Automatic (ATC )

With the optional temperature probe ( TP-07 )
0 to 65 °C.

pH Calibration

pH7, pH4, and pH10, 3 points calibration ensure the best linearity and accuracy.

Optional probe and accessories

* pH electrode..PE-03, PE-11, PE-01, PE06HD PE-04HD, PE-03K7

* ATC ( automatic temperature
probe )………………………………………TP-07

* pH 7 buffer solution……………………..PH-07 * pH 4 buffer solution……………………. PH-04

* ORP electrode……………………………. ORP-14

pH

0 to 14 pH

0.01 pH

± (0.02 pH + 2 d)

mV

-1999 to 1999 mV

1 mV

± (0.5% + 2 d)

* pH accuracy is based on calibrated meter only.

2. Conductivity/TDS

Conductivity probe

Carbon rod electrode for long life, CDPB-03 * Included

Function

* Conductivity ( uS, mS )
* TDS ( Total Dissolved Solids, PPM ) * Temperature ( °C,°F)

Temperature Compensation

Automatic from 0 to 60 °C (32 – 140 °F), with temperature compensation factor variable between 0 to 5.0% per C.

Probe Operating Temp.

0 to 60 °C.

Probe Dimension

Round, 22 mm Dia. x 120 mm length.

Optional probe and accessories

* Pt Conductivity/TDS/Salt probe, CDPB-04 * 1.413 mS Conductivity Standard

Solution, CD-14

a. Conductivity ( uS, mS )

Range

Measurement

Resolution

Accuracy

200 uS

0 to 200.0 uS

0.1 uS

± ( 2 % F.S.+ 1d) * F.S.: full scale

2 mS

0.2 to 2.000 mS

0.001 mS

20 mS

2 to 20.00 mS

0.01 mS

200 mS

20 to 200.0 mS

0.1 mS

  • *  Temperature Compensation :
    Automatic from 0 to 60 °C ( 32 – 140 °F ), with temperature compensation factor variable between 0 to 5.0% per C.
  • *  The accuracy is specified under measurement value ≦ 100 mS.

    * mS – milli Simens * @ 23± 5°C

b. TDS ( Total Dissolved Solids )

Range

Measurement

Resolution

Accuracy

200 PPM

0 to 132 PPM

0.1 PPM

± (2% F.S.+1d) * F.S. –

full scale

2,000 PPM

132 to 1,320 PPM

1 PPM

20,000 PPM

1,320 to 13,200 PPM

10 PPM

200,000 PPM

13,200 to 132,000 PPM

100 PPM

  • *  Temperature Compensation :
    Automatic from 0 to 60 °C ( 32 – 140 °F ), with temperature compensation factor variable between 0 to 5.0% per C.
  • *  he accuracy is specified under measurement value ≦ 66, 000 PPM.

    * PPM – parts per million * @ 23± 5°C

c. Temperature

Function

Measuring Range

Resolution

Accuracy

°C

0 °C to 60 °C

0.1 °C

± 0.8 °C

°F

32 °F to 140 °F

0.1 °F

± 1.5 °F

* @ 23± 5°C

3. Salt

Salt probe

Carbon rod electrode for long life, CDPB-03 * Included

Measurement Range

0 to 12 % salt ( % weight ).

Resolution

0.01 % salt.

Accuracy

± 0.5 % salt value * F.S. : full scale.

Temperature Compensation

Automatic from 0 to 60 °C (32 – 140 °F), with temperature compensation factor variable between 0 to 5.0% per C.

Probe Operating Temperature

0 to 60 °C.

Probe Dimension

Round, 22 mm Dia. x 120 mm length.

Optional probe and

* Pt Conductivity/TDS/Salt probe, CDPB-04.

4. Dissolved oxygen

Oxygen Probe

Optional, OXPB-11
The polarographic type oxygen probe .

Measurement & Range

Dissolved Oxygen

0 to 20.0 mg/L (liter).

Oxygen in Air

0 to 100.0 %.

Temperature

0 to 50 °C.

Resolution

Dissolved Oxygen

0.1 mg/L.

Oxygen in Air

0.1 % O2 .

Temperature

0.1 °C.

Accuracy (23± 5 °C)

Dissolved Oxygen

± 0.4 mg/L.

Oxygen in Air

± 0.7% O2.

Temperature

± 0.8 °C/1.5 °F.

Probe Compensation & Adj.

Temperature

0 to 50 °C, Automatic

Salt

0 to 50 % Salt

Height ( M. T.)

0 to 8900 meter

Probe Weight

335 g/0.74 LB
* Battery and proble included .

Probe Size

190 mm x 28 mm Dia. ( 7.5″ x 1.1″ Dia. )

Optional Accessories

* Oxygen probe…………………OXPB-11 * Spare Probe head with Diaphragm set ………………………………….. OXHD-04

* Probe-filling Electrolyte……..OXEL-03

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Lutron YK-2001PHA – Water Quality Meter (pH/ORP/DO/CD/TDS/Salt)”

There are no reviews yet.

SHOPPING CART

close
Hi, There!

How can I help you?

Chat

Select at least 2 products
to compare