Lutron HV-40 – High Voltage Probe

Availability:

Stok 2


Status Barang: Preorder (8 minggu)

Kondisi: Baru

Minimal Order: 1 pcs

⚠️ Barang ini Pre-Order (Full Payment). Pengiriman akan dilakukan setelah barang tersedia.

Bagikan:

DCV – 0 to 40 KV, ACV – 0 to 28 KV rms
HIGH VOLTAGE PROBE
Model : HV-40

FEATURES:
◆Attenuate Ratio: 1 : 1,000
◆Input Impedance: Approx. 1,000 MΩ
◆Output: Around 1.1 MΩ. The input impedance of external voltmeter
◆Impedance: should be 10 MΩ
◆ Safety: Meet CAT II 40000 V
◆ Max. Working Voltage:
➤ DC: 40 KV
➤ AC: Peak 40 KV or 28 KV rms (depend which values is larger)
◆ Accuracy:
➤ DCV: 1 KV to 20 KV – 1 %, 20 KV to 40 KV – 1.5 %
➤ ACV: 1 to 28 KV rms, 50/60 Hz – 5 %
◆ Temp Coefficient: Less than 200 ppm
◆ Operating Temperature: 0 to 50°C
◆ Operating Humidity: Less than 80% RH
◆ Cable Length: 1 meter

EACH UNIT INCLUDES WITH:
◆Instruction Manual

SKU: L-HV40 Kategori: Brand:
Berat 2 kg

SPECIFICATIONS

Attenuate Ratio

1 : 1000.

Input Impedance

Approx. 1000 M ohm.

Output

Around 1.1 M ohm. The input impedance of external voltmeter

Impedance

should be 10 mega ohm.

Safety

Meet CAT II 40000 V

Max. Working Voltage

DCV

DC 40 KV

ACV

Peak AC 40 KV or 28 KV rms
( depend which values is larger ).

Accuracy

DCV

1 KV to 20 KV – ± 1 %. 20 KV to 40 KV – ± 1.5 %.

ACV

1 to 28 KV rms, 50/60 Hz – ± 5 %.

Temp Coefficient

Less than 200 ppm/蚓.

Operating Temperature

0 to50°C(32 to122°F).

Operating Humidity

Less than 80% RH.

Cable Length

1 meter.

OPERATION

Connect the plugs to the volts ( Hi ) & com ( Lo ) input terminals of your voltmeter ( or Multimeter ). Select the desired range of voltmeter ( Attention : Do not use auto ranging ). Whenever possible, turn the high voltage source off before making any connections. Connect the HV probe common lead ( alligator clip ) to a good earth ground or reliable chassis ground.

SAFETY PRECAUTION & WARNING !!!

  • *  This high voltage probe must be used by the person who are trained only. Do not work alone when working with high voltage circuits & environment.
  • *  For your own safety, inspect the probes for cracks & frayed or broken leads before each use. If any defects are noted, do not use the probes.
  • *  Hands, shoes, floor & work bench must be dry. Avoid making measurements under humid, damp or other environmental conditions that might affect the safety of measurement situation.
  • *  The ground connection must always be made before the probe tip comes into contact with the high voltage & must not be removed until after the probe tip has been removed from high voltage source.
  • *  Do not attempt to take measurement from sources where the chassis or return lead is not ground.
  • *  If possible, always turn the high voltage source off before connecting or disconnecting the probe.
  • *  Before turning the high voltage on, make sure that no part of your body is in contact with the device under test.
  • *  The probe body should be kept clean & free of any conductive contamination. Clean only the exterior probe body & cables. Use a soft cotton cloth lightly moistened with a mild solution of detergent & water. Do not allow any portion of the probe to be submerged at any time.

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Lutron HV-40 – High Voltage Probe”

There are no reviews yet.

SHOPPING CART

close
Hi, There!

How can I help you?

Chat

Select at least 2 products
to compare