The WBGT-2010SD Heat Index WBGT Meter provides accurate and reliable measurements of Wet Bulb Globe Temperature (WBGT), humidity, temperature, dew point, and wet bulb temperature, making it an essential tool for monitoring and managing heat exposure in various industrial, environmental, and sports applications.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

Rp4.123.650,0

Stok 5

Bagikan:

HEAT INDEX WBGT METER
Model: WBGT-2010SD

OVERVIEW:
The WBGT-2010SD Heat Index WBGT Meter provides accurate and reliable measurements of Wet Bulb Globe Temperature (WBGT), humidity, temperature, dew point, and wet bulb temperature, making it an essential tool for monitoring and managing heat exposure in various industrial, environmental, and sports applications.

FEATURES:
◆ Measurement: WBGT value (Indoor/Outdoor Wet bulb globe temperature), Black globe temperature, Humidity, Air temperature, Wet bulb temperature, Dew point Temp.
◆ Adjustable WBGT alarm setting, if the WBGT value over the alarm threshold, the buzzer will sound along with the flashing Display
◆ Using to control and monitor of physical activity in hot environment to limit the danger of heat related injuries
◆ Globe temperature measurement use the Pt sensor, high accuracy
◆ Fast humidity measuring response time
◆ Direct measurement of the radiation effect with a brass black ball in 75 mm dia
◆ Sensor protecting mechanism
◆ Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder , sampling time set from 1 second to 3600 seconds
◆ Manual datalogger is available
◆ LCD with green light backlight, easy reading
◆ Can default auto power off or manual power off
◆ Data hold, record max. and min. reading
◆ Microcomputer circuit, high accuracy
◆ Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter
◆ RS232/USB PC COMPUTER interface

EACH UNIT INCLUDES WITH:
◆ Instruction manual
◆ Black brass ball (with sensor)
◆ Soft carrying case

OPTIONAL ACCESSORIES:
◆ SD Card
◆ AC to DC 9V adapter
◆ USB cable, USB-01
◆ RS232 cable, UPCB-02
◆ Data Acquisition software, SW-U801-WIN
◆ Hard carrying case, CA-08

SKU: L-WBGT2010SD Kategori: Brand:
Berat 1 kg

GENERAL SPECIFICATIONS

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).

Measurement

* Wet bulb globe temperature ( WBGT ) @ Indoor/Outdoor

* Black globe temperature ( TG ) * Air temperature ( TA )
* Wet bulb temperature ( WB ) * Humidity

* Dew point temperature

WBGT formula * Wet bulb

globe Temp.

Indoor/Outdoor and no sun : WBGT = ( 0.7 x WB ) + ( 0.3 x TG )

Outdoor and full sun :
WBGT = ( 0.7 x WB ) + ( 0.2 x TG ) + ( 0.1 x TA )

WBGT alarm setting

Adjustable WBGT alarm setting, if the WBGT value over the alarm threshold, the buzzer will sound along with the flashing Display.

Datalogger Sampling Time Setting range

Auto

1 second to 3600 seconds
@ Sampling time can set to 1 second,

but memory data may loss.

Manual

Push the data logger button once will save data one time. @ Set the sampling time to

0 second.
@ Manual mode, can also select the

1 to 99 position ( Location ) no.

Data error no.

0.1% of total saved data max.

Memory Card

SD memory card. 1 GB to 16 GB

Advanced setting

  • *  Set clock time ( Year/Month/Date, Hour/Minute/ Second )
  • *  Set WBGT alarm value
  • *  Decimal point of SD card setting
  • *  Auto power OFF management
  • *  Set beep Sound ON/OFF
  • *  Select the temperature unit to °C or °F.
  • *  Set sampling time
  • *  SD memory card Format

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Sampling Time of Display

Approx. 1 second.

Data Output

RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.

* Connect the optional USB cable USB-01 will get the USB plug.

Operating Temperature

0 to 50 °C.

Operating Humidity

Less than 85% R.H.

Power Supply

* Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.

* ADC 9V adapter input. ( AC/DC power adapter is optional ).

Power Current

Normal operation ( w/o SD card save data and LCD Backlight is OFF) :

Approx. DC 5 mA.

When SD card save the data but and LCD Backlight is OFF) :

Approx. DC 25 mA.

* AIf LCD backlight on, the power consumption will increase approx. 11 mA.

Weight

489 g/1.08 LB.

Dimension

Meter

177 x 68 x 45 mm

Black brass ball

(7.0 x 2.7x 1.9 inch) Round, 75 mm dia

Standard Accessories Included

* Instruction manual……………………….1 PC * Black brass ball ( with sensor )……. 1 PC * Soft carrying case, CA-05B…………….1 PC

Optional Accessories

  • *  SDCard(2GB)
  • *  AC to DC 9V adapter.
  • *  USB cable, USB-01.
  • *  RS232 cable, UPCB-02.
  • *  Data Acquisition software,SW-U801-WIN.
  • *  Hard carrying case, CA-08,

    Size : 370 x 310 x 115 mm.

ELECTRICAL SPECIFICATIONS (23± 5 °C)

Wet bulb globe temperature ( WBGT )

Range

°C

Indoor

0 °C to 59 °C

Outdoor

0 °C to 56 °C

°F

Indoor

32 to 138 °F

Outdoor

32 to 132 °F

Accuracy * Indoor

°C

± 1 °C ( 15 to 59 °C ) ± 1.5 °C ( Others )

°F

± 1.8 °F ( 59 to 138 °F ) ± 2.7 °F ( Others )

Accuracy * Outdoor

°C

± 1.5 °C ( 15 to 56 °C ) ± 2 °C ( Others )

°F

± 2.7 °F ( 59 to 132 °F ) ± 3.6 °F ( Others )

WBGT Formula :

Indoor
( Outdoor and no sun )

WBGT= 0.7WB + 0.3TG

Outdoor
( Outdoor and full sun )

WBGT= 0.7WB + 0.2TG + 0.1TA

Air temperature ( TA )

Range

°C

0 to 50 °C

°F

32 to 122 °F.

Resolution

°C

0.1 °C

°F

0.1 °F

Accuracy
@ 15 to 40 °C

°C

± 0.8 °C

°F

± 1.5 °F

Black globe temperature ( TG )

Range

°C

0 to 80 °C

°F

32 to 176 °F.

Resolution

°C

0.1 °C

°F

0.1 °F

Accuracy
@ 15 to 40 °C

°C

± 0.6 °C

°F

± 1.1 °F

Humidity

Range

5 % to 95 % R.H.

Resolution

0.1 % R.H.

Accuracy

≧70% RH :
± (3% reading + 1% RH).

< 70% RH :
± 3% RH.

Dew Point Temp.

°C

Range

-25.3 °C to 48.9 °C

Resolution

0.1 °C

°F

Range

-13.5 °F to 120.1 °F.

Resolution

0.1 °F .

Remark : * Dew Point Temp. value is calculated from the Humidity/Air Temp. measurement automatically.

* The Dew Point Temp. accuracy is sum accuracy value of Humidity & Air Temperature measurement..

Wet bulb Temp.

°C

Range

-21.6 °C to 50.0 °C

Resolution

0.1 °C

°F

Range

-6.9 °F to 122.0 °F.

Resolution

0.1 °F .

Remark : * Wet bulb display value is calculated from the Humidity/Air Temp. measurement automatically. * The Dew Point accuracy is sum accuracy value of

Humidity & Air temperature measurement..

Recommendations to heat exposure level for working and physical activity.

( Permissible heat exposure threshold limit )

Work/rest regimen ( Each hour )

Light

Moderate

Heavy

Continuous work

30 °C
( 86 °F )

26.7 °C ( 80 °F )

25 °C
( 77 °F )

75% work, 25% rest

30.6 °C ( 87 °F )

28 °C
( 82 °F )

25.9 °C ( 78 °F )

50% work, 50% rest

31.4 °C ( 89 °F )

29.4 °C ( 85 °F )

27.9 °C ( 82 °F )

25% work, 75% rest

32.2 °C ( 90 °F )

31.1 °C ( 88 °F )

30 °C
( 86 °F )

Source : AGGIH 1992 ( The American Conference of Governmental Industrial Hygienists )

WBGT INDEX and PHYSICAL EXERCISE

WBGT

Flag

Activity Intensity

< 26.7 °C ( < 80 °F )

White

Normal activity.
Caution should be taken.

26.7 to 29.4 °C ( 80 to 84.9 °F )

Green

Descretion is required in planning intense physical activity.

29.5to31 °C
( 85 to 87.9 °F )

Yellow

Intense activity for new and unacclimatized persons should be curtailed.

31.1 to 32.2 °C ( 88 to 89.9 °F )

Red

Intense exercise must be curtailed for those
with less than 12 weeks training in hot weather. Be on high alert

≧32.2 °C ( ≧ 90 °F )