DISSOLVED OXYGEN METER
Model: DO-5512SD

OVERVIEW:
The DO-5512SD Dissolved Oxygen Meter offers accurate and reliable dissolved oxygen measurements with real-time data logging capabilities, making it an essential tool for various industrial and environmental applications.

FEATURES:
◆ Precision Dissolved Oxygen measurement
◆ Dissolved oxygen : 0 to 20.0 mg/L
◆ Dissolved oxygen meter use the polar graphic type oxygen probe with temperature sensor, high precision measurement for Dissolved Oxygen (DO) and temperature measurement
◆ Heavy duty dissolved oxygen probe, probe head can connect with BOD bottle
◆ DO use the automatic Temp. compensation
◆ DO meter build in % SALT Mountain Height #34; compensation value adjustment
◆ Separate probe, easy for operation of different measurement environment ➤ Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder , sampling time set from 1 sec to 8 hour 59 min. 59 sec
◆ Manual datalogger is available (set the sampling time to 0), during execute the manual datalogger function, it can set the different position (location) No. (position 1 to position 99)
◆ Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer, it can down load the all the measured value with the time information (year/month/date/hour/minute/second) to the Excel directly, then user can make the further data or graphic analysis by themselves.

EACH UNIT INCLUDES WITH:
◆ Oxygen probe, OXPB-11
◆ Hard carrying case
◆ Operation manual
◆ Spare Probe head with Diaphragm, OXHD-04
◆ Probe-filling Electrolyte, OXEL-03

OPTIONAL ACCESSORIES:
◆ RS232 cable, UPCB-02
◆ USB cable, USB-01
◆ Data Acquisition software, SW-U801-WIN
◆ SD Memory Card

SKU: L-DO5512SD Kategori: Brand:
Berat 1,5 kg

SPECIFICATIONS

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).

Measurement

Dissolved Oxygen
Air oxygen ( for reference only )

Measurement & Range

Dissolved Oxygen

0 to 20.0 mg/L ( liter ).

Oxygen in Air

0 to 100.0 %.

Temperature

0 to 50 °C.

Resolution

Dissolved Oxygen

0.1 mg/L.

Oxygen in Air

0.1 % O2 .

Temperature

0.1 °C.

Accuracy (23± 5 °C)

Dissolved Oxygen

± 0.4 mg/L.

Oxygen in Air

± 0.7% O2.

Temperature

± 0.8 °C/1.5 °F.

Probe Compensation & Adj.

Temperature

0 to 50 °C, Automatic

Salt

0 to 50 % Salt

Height ( M. T.)

0 to 8900 meter

Oxygen Probe

The polarographic type oxygen probe with temp. sensor.

Memory Card

SD memory card. 1 GB to 16 GB.

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Datalogger Sampling Time Setting range

Auto

1 sec to 8 hour 59 min. 59 sec. @ Sampling time can set to 1 second,

but memory data may loss.

Manual

Push the data logger button once will save data one time. @ Set the sampling time to

0 second.
@ Manual mode, can also select the

1 to 99 position ( Location ) no.

Advanced setting

  • *  SD memory card Format
  • *  Set clock time ( Year/Month/Date,

    Hour/Minute/ Second )

  • *  Set sampling time
  • *  Auto power OFF management
  • *  Set beep Sound ON/OFF
  • *  Decimal point of SD card setting
  • *  Set temperature unit to °C or °F
  • *  Set DO salt% compensation value
  • *  Set DO height ( meter ) compensation value
  • *  Set DO height ( feet ) compensation value

Sampling Time of Display

Approx. 1 second.

Data Output

RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.

* Connect the optional USB cable USB-01 will get the USB plug.

Operating Temperature

0 to 50 °C.

Operating Humidity

Less than 85% R.H.

Power Supply

* Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.

* ADC 9V adapter input. ( AC/DC power adapter is optional ).

Power Current

Normal operation ( w/o SD card save data and LCD Backlight is OFF) :

Approx. DC 14 mA.

When SD card save the data and LCD Backlight is OFF) :

Approx. DC 37 mA.

* AIf LCD backlight on, the power consumption will increase approx. 12 mA.

Weight

Meter

489 g/1.08 LB.

Probe

335 g/0.74 LB

Dimension

Meter

177 x 68 x 45 mm (7.0 x 2.7x 1.9 inch)

Probe

190 mm x 28 mm Dia. ( 7.5″ x 1.1″ Dia. )

Accessories Included

  • *  Oxygen probe ( OXPB-11 )…………… 1 PC.
  • *  Hard carrying case ( CA-06 )………….1 PC.
  • *  Operation manual……………………….1 PC.
  • *  Spare Probe head with Diaphragm

    OXHD-04…………………………………. 2 set

  • *  Probe-filling Electrolyte

    OXEL-03………………………………….. 1 set

Optional probe and accessories

  • *  Oxygen probe………………….. OXPB-11
  • *  Spare Probe head with

    Diaphragm set…………………..OXHD-04

  • *  Probe-filling Electrolyte………. OXEL-03
  • *  RS232 cable……………………..UPCB-02
  • *  USB cable……………………….. USB-01
  • *  Data Acquisition software

    …………………………….SW-U801-WIN

  • *  AC to DC 9V adapter

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Lutron DO-5512SD – Dissolved Oxygen Meter with SD Card Data Recorder”

There are no reviews yet.

SHOPPING CART

close
Hi, There!

How can I help you?

Chat

Select at least 2 products
to compare