The YK-37UVSD UVA & UVC Light Meter provides accurate and reliable measurements of UVA and UVC irradiance, making it an essential tool for various industrial, environmental, and laboratory applications. The device also supports Type K/J thermocouple thermometer functionality, enhancing its versatility.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

Rp6.360.300,0

Stok 5

Bagikan:

UVA, UVC LIGHT METER
Model: YK-37UVSD

OVERVIEW:
The YK-37UVSD UVA & UVC Light Meter provides accurate and reliable measurements of UVA and UVC irradiance, making it an essential tool for various industrial, environmental, and laboratory applications. The device also supports Type K/J thermocouple thermometer functionality, enhancing its versatility.

KEY FEATURES:
◆ UVA, UVC light measurement in one meter
◆ Exactly same spec wtih Lutron UVA-365SD and UVC-254SD
◆ Microprocessor circuit provides high reliability and durability
◆ Separate UV LIGHT probe allows user to measure the UV light at an optimum position
◆ Real time SD memory card Datalogger
◆ Type K, Type J thermocouple thermometer

SPECIFICATION:
◆ UVA Light Measurement Ranges:
– 2 mW/cm² (Resolution: 0.001 mW/cm²)
– 20 mW/cm² (Resolution: 0.01 mW/cm²)
– Accuracy: ±(4% FS + 2 dgt)
– Sensor Spectrum: 260 nm to 390 nm
– Sensor Structure: Exclusive UVA photo sensor with cosine correction filter
◆ UVC Light Measurement Ranges:
– 2 mW/cm² (Resolution: 0.001 mW/cm²)
– 20 mW/cm² (Resolution: 0.01 mW/cm²)
– Accuracy: ±(4% FS + 2 dgt)
– Sensor Spectrum: 200 nm to 280 nm
– Sensor Structure: Exclusive UVC photo sensor with cosine correction filter
◆ Type K Range: -50.0 to 1300.0℃ (Resolution: 0.1℃)
◆ Type J Range: -50.0 to 1200.0℃ (Resolution: 0.1℃)

EACH UNIT INCLUDES WITH:
◆ Instruction manual
◆ UVA probe
◆ UVC probe
◆ Hard Carrying Case

OPTIONAL ACCESSORIES:
◆ SD Card
◆ Type K Thermocouple Probes TP-01, TP-02A, TP-03, TP-04
◆ AC to DC 9V Adapter
◆ USB cable, USB-01
◆ RS232 cable, UPCB-02
◆ Data Acquisition software, SW-U801-WIN

SKU: L-YK37UVSD Kategori: Brand:
Berat 1,5 kg

GENERAL SPECIFICATIONS

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ).

Measurement

UV Light : UVA, UVC Type K/J thermometer

UVA, UVC

slectrion

Selct by pushin the front button.

UV Sensor spectrum cover range

240 nm to 390 nm.

UV ‘sensor structure

The exclusive UV photo sensor with the cosine correction filter.

UV light zero adjustment

By push button.

Memory with Recall

Records Maximum & Minimum reading with recall.

Datalogger Sampling Time Setting range

Auto

1 second to 3600 seconds
@ Sampling time can set to 1 second,

but memory data may loss.

Manual

Push the data logger button once will save data one time. @ Set the sampling time to

0 second.
@ Manual mode, can also select the

1 to 99 position ( Location ) no.

Memory Card

SD memory card. 1 GB to 16 GB.

Advanced setting

* Set clock time ( Year/Month/Date, Hour/Minute/ Second )

* Decimal point of SD card setting * Auto power OFF management

Advanced setting

* Set beep Sound ON/OFF
* Set thermometer type to Type K or Type J * Set temperature unit to °C or °F
* Set sampling time
* SD memory card Format

Temperature Compensation

Automatic temp. compensation for the type K/J thermometer.

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Sampling Time of Display

Approx. 1 second.

Data Output

RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.

* Connect the optional USB cable USB-01 will get the USB plug.

Operating Temperature

0 to 50 °C.

Operating Humidity

Less than 85% R.H.

Power Supply

* Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 6 PCs, or equivalent.

* ADC 9V adapter input. ( AC/DC power adapter is optional ).

Power Current

Normal operation ( w/o SD card save data and LCD Backlight is OFF) :

Approx. DC 6.5 mA.

When SD card save the data but and LCD Backlight is OFF) :

Approx. DC 30 mA.

* AIf LCD backlight on, the power consumption will increase approx. 16 mA.

Weight

Meter

351 g.

UVA probe

100 g.

UVC probe

103 g.

Meter

177 x 68 x 45 mm

UVA probe

Head

45 mm dia x 32 mm

Handle

125 x 24 mm dia.

UVC probe

38 mm DIA. x 25 mm

Accessories Included

* Instruction manual………………………1 PC * UVA light sensor…………………………1 PC * UVC light sensor…………………………1 PC * Hard carrying case, CA-06…………….1 PC

Optional Accessories

SD Card ( 2 GB )
Type K thermocouple probe.
AC to DC 9V adapter.
USB cable, USB-01.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.

ELECTRICALSPECIFICATIONS (23±5°C)

UV Light ( UVA, UVC )

Measurement ranges & resolution

Range 1 : 2 mW/cm^2 :
1.999 mW/cm^2 x 0.001 mW/cm^2

Range 2 : 20 mW/cm^2 :
19.99 mW/cm^2 x 0.01 mW/cm^2

Accuracy

± ( 4 % FS + 2 dgt ). FS : full scale

  • *  UVA Calibration is executed under the UVA light &

    and compare with the standard UVA light meter.

  • *  UVC Calibration is executed under the UVC light & and compare with the standard UVC light meter.

Type K/J thermometer

Sensor Type

Resolution

Range

Accuracy

Type K

0.1 °C

-50.0 to 1300.0 °C -50.1 to -100.0 °C

± (0.4%+0.5°C) ± (0.4%+1°C)

0.1 °F

-58.0 to 2372.0 °F -58.1 to -148.0 °F

± (0.4%+1°F) ± (0.4%+1.8°F)

Type J

0.1 °C

-50.0 to 1200.0 °C -50.1 to -100.0 °C

± (0.4%+0.5°C) ± (0.4%+1°C)

0.1 °F

-58.0 to 2192.0 °F -58.1 to -148.0 °F

± (0.4%+1°F) ± (0.4%+1.8°F)