Lutron YK-2005AM – Digital Anemometer Real Time Data Logger

Availability:

Stok 1


The Lutron YK-2005AM is a versatile and robust digital vane anemometer designed for precise measurement of air velocity, airflow, and temperature. Equipped with a real-time data logger and a heavy-duty metal vane sensor, this instrument delivers accurate environmental readings across a wide range of airflow conditions.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

Rp4.684.200,0

Stok 1

Bagikan:

ANEMOMETER
Model: YK-2005AM

FEATURES:
◆ Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,
◆ Air flow : CMM (m^3/min) and CFM (ft^3/min)
◆ Air temperature
◆ Type K/ Type J thermocouple thermometer
◆ Real time data logger, build in clock (hour-min.-sec., year-month-date)
◆ Auto or manual data record, 16,000 Data logger no
◆ Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds
◆ RS232 computer interface
◆ Can default auto power off or manual power off
◆ Can default the air velocity, air flow, Temp. unit
◆ Air flow measurement can set the area dimension
◆ Multi function with easy operation
◆ Low-friction ball vane wheels make sure high accuracy in high & low velocities
◆ Metal vane, high reliability
◆ Large LCD with multiple display
◆ Data hold, record max. and min. reading
◆ Microcomputer circuit provides special function & offer high accuracy
◆ Air Temp. used thermistor sensor, fast response time
◆ Power by UM3 (1.5 V) x 4 batteries or DC 9V adapter
◆ RS232 PC serial interface
◆ Separate probe, easy for operation of different measurement environment
◆ Wide applications: use this anemometer to check air conditioning & heating systems, measure air velocities, wind temperature…etc

EACH UNIT INCLUDES WITH:
◆ Instruction manual
◆ Anemometer probe
◆ Carrying case

OPTIONAL ACCESSORIES:
◆ Type K thermocouple probe
◆ RS232 cable, UPCB-02
◆ USB cable, USB-01
◆ Data Acquisition software, SW-U801-WIN

SKU: L-YK2005AM Kategori: Brand:
Berat 2 kg

General Specifications

Circuit

Custom one-chip of microprocessor LSI circuit.

Display

LCD size : 58 mm x 34 mm.

Measurement

Unit

Air velocity:

m/S (meters per second)
Km/h ( kilometers per hour ) Ft/min ( feet per minute )
Knots ( nautical miles per hour ) Mile/h ( miles per hour )

Air flow:
CMM ( m^3/min., cube meter per min. ) CFM ( m^3/min., cube feet per min. )

Air temperature: °C, °F

Type K/ Type J thermometer. °C, °F

Sampling Time of Data Logger

Manual

Push the data logger button once will save data one time. @Set the sampling time to

0 second

Auto

2 sec to 8 hour 59 min. 59 sec.

Sensor Structure

Air velocity & Air flow :
Conventional twisted van arm and low friction ball bearing design, vane use metal material.

Air temperature : Thermistor.

Type K/ Type J thermometer. Thermocouple

Temperature Compensation

Automatic temp. compensation for the Type K/J thermometer.

Data Hold

Freeze the display reading.

Memory Recall

Maximum & Minimum value.

Sampling Time of display

Approx. 1 second.

Power off

Auto shut off saves battery life or manual off by push button.

Data Output

RS 232 PC serial interface.

Operating Temperature

0 to 50 °C.

Operating Humidity

Less than 80% R.H.

Power Supply
* main instrument

DC 1,5 V battery ( UM3 ) x 4 PCs, ( Heavy duty type ).

DC 9V adapter input.
@ AC/DC power adapter is optional.

Power Supply * clock module

DC 3V silver battery.

Type : CR2032.

Power Current

Approx. DC 21.5 mA @ Main instrument.

DC 27.5 mA.
@ Main instrument. + Anemometer probe.

Weight

515 g/ 1.13 LB. @ Battery is included.

Dimension

Main instrument : 203 x 76 x 38 mm

Anemometer sensor head : Round, 72 mm Dia.

Accessories Included

Instruction manual……………………1 PC Anemometer probe…………………..1 PC DC 3V silver battery, CR2032…….. 1 PC Carrying case…………………………. 1 PC

Optional Accessories

Type K thermocouple probe.
AC to DC 9V adapter.
RS232 cable/UPCB-02, USB cable/USB-01 Data Acquisition software, SW-U801-WIN. Data Logger software, SW-DL2005.

Electrical Specifications (23± 5 °C)

Air velocity

Measurement

Range

Resolution

Accuracy

m/S

0.4 – 30.0 m/s

0.1 m/S

± ( 2%+0.2 m/S)

Km/h

1.4 – 126.0 km/h

0.1 Km/h

± ( 2%+0.8 Km/h)

Mile/h

0.9 – 78.3 mph

0.1 Mile/h

± ( 2%+0.4 Mile/h)

Knots

0.8 – 68.0 knots

0.1 Knots

± ( 2%+0.4 Knots)

Ft/min

79 – 6890 ft/min

1 Ft/min

± ( 2%+40 Ft/min)

Air flow

Measurement Range Resolution Area

CMM (m^3/min.) 0-999,900 m^3/min. 0.001-100 0.001-9,999 m^3/min.

CFM (ft^3min.). 0-999,900 ft^3/min. 0.001-100 0.001-9,999 ft^3/min.

Air temperature

Measuring Range 0 °C to 50 °C/32 °F to 122 °F

Resolution 0.1 °C/0.1 °F

Accuracy ± 0.8 °C/1.5 °F

Type K/J thermometer

Sensor Type

Reso- lution

Range

Accuracy

Type K

0.1 °C

-50.0 to 1300.0 °C

± (0.2%+0.5°C)

-50.1 to -100.0 °C

± (0.2%+1°C)

0.1 °F

-58.0 to 2372.0 °F

± (0.2%+1°F)

-58.1 to -148.0 °F

± (0.2%+1.8°F)

Type J

0.1 °C

-100.0 to 1100.0 °C

± (0.2%+0.5°C)

-50.1 to -100.0 °C

± (0.2%+1°C)

0.1 °F

-58.0 to 2012.0 °F

± (0.2%+1°F)

-58.1 to -148.0 °F

± (0.2%+1.8°F)

 

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Lutron YK-2005AM – Digital Anemometer Real Time Data Logger”

There are no reviews yet.

SHOPPING CART

close
Hi, There!

How can I help you?

Chat

Select at least 2 products
to compare