- Remove this product from my favorite's list.
- Add this product to my list of favorites.
- Send to a friend
Fluke Ti125 Infrared Camera
Thermal Camera
The Optimal Choice in Advanced Infrared Troubleshooting
Call 022 7106162
Thermal Camera
The Optimal Choice in Advanced Infrared Troubleshooting
Call 022 7106162
Capturing properly focused images just got easier with Fluke exclusive IR-OptiFlex™ focus system. Now it's easier than ever to communicate your findings with focus-free image capture and the flexibility to switch to manual mode for those close-in tight shots. The Ti125, a Thermal Imaging Camera, also includes Fluke's exclusive point-and-shoot IR-Fusion® Technology – the blending of digital and infrared images into a single image making precise documentation quick and easy, as well as the ability to produce partially transparent images with AutoBlend™.
The Fluke Ti125 temperature range is -20 °C to 350 °C (-4 °F to +662 °F), which is ideal for most industrial applications. Keep track of inspection locations by adding additional digital images (IR-PhotoNotes®) that will help you reference the location or unique situations at the inspection site. Carrying pen and paper is no longer necessary with voice annotation and the electronic 8–point Cardinal Compass easily communicates the inspection site location. Spend more time fixing problems with less manual documentation by capturing more data quickly and uploading directly to your PC.
For applications that require a high temperature range and low thermal sensitivity (NETD), the Ti400 is an alternative choice. It features wireless connectivity for quick and easy sharing of images, LaserSharp® Auto Focus for consistently in-focus images – every, single, time and a ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation.
Easily Share High Quality Video with Co-Workers and Clients with Video Streaming
View inspections on your PC easily with video streaming straight from your thermal imaging camera via the USB port; your ability to clearly show co-workers or customers issues, just got easier.
With CNX™ multi-tool connectivity you can capture five additional measurements via Fluke CNX AC current, voltage and iFlex clamp modules. As always, Fluke SmartView® software is included at no additional charge.
Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125.
IR resolution (FPA size) | 160 x 120 FPA Uncooled Microbolometer |
Spectral band | 7.5 μm to 14 μm (long wave) |
Capture or refresh rate | 9 Hz or 30 Hz versions |
NETD (thermal sensitivity) | ≤ 0.10 °C at 30 °C target temp (100 mK) 0.10 °C at 30 °C target temp (100 mK) |
FOV (field of view) | 22.5 °H x 31 °V |
IFOV (spatial resolution) | 3.39 mRad |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +350 °C (-4 °F to +662 °F) |
Temperature measurement accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
Focus mechanism | IR-OptiFlex™ focus system |
IR-Fusion® technology | PIP, FULL IR, FULL VISIBLE, AutoBlend™ |
CNX wireless enabled | Yes |
Color alarms | High temperature, low temperature, isotherm |
Standard palettes | Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber |
Ultra Contrast™ palettes | Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber |
Hot/cold markers | Yes |
User definable spot markers | Three on camera and in SmartView® |
Centerbox (MIN/AVG/MAX) | Yes |
Level and span control | Manual and auto |
Minimum span in auto mode | 5 °C |
Minimum span in manual mode | 2.5 °C |
Minimum IR focus distance | 15.25 cm (6 in) |
Weight | 0.726 kg (1.6 lb) |
Size | 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) |
LCD display | 3.5 inch diagonal (portrait format) |
Visible camera | 2 megapixel industrial-grade |
Minimum automatic parallax correction | ~18-22 inches |
IR-PhotoNotes™ annotation system | Yes (3 images) |
Laser pointer | Yes |
Torch | Yes |
Electronic (cardinal) compass | Yes |
Emissivity correction | Yes |
Transmission correction | Yes |
Background (reflected) compensation | Yes |
Voice annotation (audio) | Yes (60 seconds) per image |
Multi-mode video output | Streaming USB video output (infrared, visible and IR-Fusion modes) |
Multi-mode video recording (standard avi w/ mpeg encoding) | Yes (AVI with MPEG encoding, up to 5 minutes) |
Multi-mode video recording (radiometric .Is3) | Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene |
Memory review | Thumbnail review |
Battery (field-replaceable, rechargeable) | Two |
Battery life | 4+ hours (each)* |
External battery charging base | Yes |
Charging power supply | Yes |
Drop test | 2 meter (6.5 feet) |
Ingress protection (IP) rating (IEC 60529) | IP 54 |
Recommended calibration cycle | Two-years |
Multifunction card reader | Included |
Memory storage | 2 GB SD memory card |
Direct download capability | Mini USB download direct to PC |
Operating temperature range | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature range | -20 °C to +50 °C (-4 °F to 122 °F) |
Operating humidity | Operating and storage 10 % to 95 %, non-condensing |
Vibration and shock | 2G, IEC 68-2-26 and 25G, IEC 68-2-29 |
Safety standards | CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
C Tick | IEC/EN 61326-1 |
EMI, RFI, EMC | EN61326-1; FCC Part 5 |
User manuals | Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian |
Standard warranty period | Two-years |
Extended warranty and service plans | Yes |
*Assumes 50% brightness of LCD