Fluke Ti125 Infrared Camera

Thermal Camera

The Optimal Choice in Advanced Infrared Troubleshooting

More details

Call 022 7106162

Add Subtract

Capturing properly focused images just got easier with Fluke exclusive IR-OptiFlex™ focus system. Now it's easier than ever to communicate your findings with focus-free image capture and the flexibility to switch to manual mode for those close-in tight shots. The Ti125, a Thermal Imaging Camera, also includes Fluke's exclusive point-and-shoot IR-Fusion® Technology – the blending of digital and infrared images into a single image making precise documentation quick and easy, as well as the ability to produce partially transparent images with AutoBlend™.

The Fluke Ti125 temperature range is -20 °C to 350 °C (-4 °F to +662 °F), which is ideal for most industrial applications. Keep track of inspection locations by adding additional digital images (IR-PhotoNotes®) that will help you reference the location or unique situations at the inspection site. Carrying pen and paper is no longer necessary with voice annotation and the electronic 8–point Cardinal Compass easily communicates the inspection site location. Spend more time fixing problems with less manual documentation by capturing more data quickly and uploading directly to your PC.

For applications that require a high temperature range and low thermal sensitivity (NETD), the Ti400 is an alternative choice. It features wireless connectivity for quick and easy sharing of images, LaserSharp® Auto Focus for consistently in-focus images – every, single, time and a ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation.

Easily Share High Quality Video with Co-Workers and Clients with Video Streaming

View inspections on your PC easily with video streaming straight from your thermal imaging camera via the USB port; your ability to clearly show co-workers or customers issues, just got easier.

With CNX™ multi-tool connectivity you can capture five additional measurements via Fluke CNX AC current, voltage and iFlex clamp modules. As always, Fluke SmartView® software is included at no additional charge.

Features

    • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
    • Always have references handy—IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
    • Find problems faster and easier—IR-Fusion® with AutoBlend™ mode—Accurately identify potential issues by combining digital and IR images with AutoBlend. It blends digital and partially transparent IR images into a single information-filled image.
    • Capture current measurements fast and conveniently from up to five wireless modules at once using your Fluke thermal imaging camera and CNX wireless modules.
    • Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
    • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).

    Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125.

  • Specs

  • IR resolution (FPA size)160 x 120 FPA Uncooled Microbolometer
    Spectral band7.5 μm to 14 μm (long wave)
    Capture or refresh rate9 Hz or 30 Hz versions
    NETD (thermal sensitivity)≤ 0.10 °C at 30 °C target temp (100 mK)
     0.10 °C at 30 °C target temp (100 mK)
    FOV (field of view)22.5 °H x 31 °V
    IFOV (spatial resolution)3.39 mRad
    Temperature measurement range (not calibrated below -10  °C)-20 °C to +350 °C (-4 °F to +662 °F)
    Temperature measurement accuracy± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
    Focus mechanismIR-OptiFlex™ focus system
    IR-Fusion® technologyPIP, FULL IR, FULL VISIBLE, AutoBlend™
    CNX wireless enabledYes
    Color alarmsHigh temperature, low temperature, isotherm
    Standard palettesBlue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
    Ultra Contrast™ palettesBlue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
    Hot/cold markersYes
    User definable spot markersThree on camera and in SmartView®
    Centerbox (MIN/AVG/MAX)Yes
    Level and span controlManual and auto
    Minimum span in auto mode5 °C
    Minimum span in manual mode2.5 °C
    Minimum IR focus distance15.25 cm (6 in)
    Weight0.726 kg (1.6 lb)
    Size28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
    LCD display3.5 inch diagonal (portrait format)
    Visible camera2 megapixel industrial-grade
    Minimum automatic parallax correction~18-22 inches
    IR-PhotoNotes™ annotation systemYes (3 images)
    Laser pointerYes
    TorchYes
    Electronic (cardinal) compassYes
    Emissivity correctionYes
    Transmission correctionYes
    Background (reflected) compensationYes
    Voice annotation (audio)Yes (60 seconds) per image
    Multi-mode video outputStreaming USB video output (infrared, visible and IR-Fusion modes)
    Multi-mode video recording (standard avi w/ mpeg encoding)Yes (AVI with MPEG encoding, up to 5 minutes)
    Multi-mode video recording (radiometric .Is3)Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
    Memory reviewThumbnail review
    Battery (field-replaceable, rechargeable)Two
    Battery life4+ hours (each)*
    External battery charging baseYes
    Charging power supplyYes
    Drop test2 meter (6.5 feet)
    Ingress protection (IP) rating (IEC 60529)IP 54
    Recommended calibration cycleTwo-years
    Multifunction card readerIncluded
    Memory storage2 GB SD memory card
    Direct download capabilityMini USB download direct to PC
    Operating temperature range-10 °C to +50 °C (14 °F to 122 °F)
    Storage temperature range-20 °C to +50 °C (-4 °F to 122 °F)
    Operating humidityOperating and storage 10 % to 95 %, non-condensing
    Vibration and shock2G, IEC 68-2-26 and 25G, IEC 68-2-29
    Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
    C TickIEC/EN 61326-1
    EMI, RFI, EMCEN61326-1; FCC Part 5
    User manualsCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
    Standard warranty periodTwo-years
    Extended warranty and service plansYes

    *Assumes 50% brightness of LCD