POWER ANALYZER 3390-10

Power analyzers

DC, 0.5 Hz to 150 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy.

More details

Call 022 7106162

Add Subtract

 

Overview

• Super precise ±0.1% accuracy model to meet the demanding needs of today
• Switch from one range to another and still maintain the same ±0.1% accuracy on all ranges
• Guaranteed accuracy period is extended another 6 months from the basic Model 3390 (other functions remain the same)
• Advanced motor analysis functions (measures the electric angle and supports vector control)
• High-speed harmonic analysis function (50 ms data refresh rate)
• Noise analysis function for inverters (using FFT analysis technology)
• Inverter power measurement with the convenience of clamp on sensors

■ Basic specifications (Accuracy guaranteed for 1 year)

Measurement line typeSingle-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel
Measurement itemsVoltage, Current, Voltage/current waveform peak, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, Current integration, Power integration, Efficiency, Loss, Voltage/current ripple factor
 Noise measurement (FFT processing): RMS spectrum of voltage/current
Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor
 Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output
Harmonic measurementInput: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz,
Number of harmonic orders: Max. 100th order
Noise measurementNumber of channels: 1 ch (select one channel from CH1 to CH4),
Maximum analysis frequency: 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz
Measurement rangeVoltage range: 15 to 1500 V, 7 ranges
Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated)
Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range)
Frequency range: 0.5 Hz to 5 kHz
Basic accuracy (45Hz to 66Hz)Voltage: ±0.05 % rdg. ±0.05 % f.s.
Current: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)
Active power: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors)
Note: Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy.
Synchronization frequency range0.5 Hz to 5 kHz
Frequency bandDC, 0.5 Hz to 150 kHz
Data update rate50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz)
Display refresh rate200 ms (Independent of internal data update rate; waveform and FFT depend on the screen)
Data save intervalOFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings
External interfacesLAN, USB (communication/ memory), RS-232C, CF card, Synchronization control
Power supply100 to 240 V AC, 50/60 Hz, 140 VA max.
Dimensions and mass340 mm (13.39 in) W × 170 mm (6.69 in) H × 157 mm (6.18 in) D, 4.8 kg (169.3 oz)
AccessoriesInstruction Manual for Model 3390-10 × 1, Instruction Manual for Model 3390 × 1, Power cord × 1, Measurement Guide × 1, USB cable × 1, Measurement cable label sheet × 2, D-sub connector × 1 (when 9792 or 9793 is installed)

■ Specifications for the Motor Testing Option (Accuracy guaranteed for 1 year)

Number of input channels3 channels, CH A: Torque signal input (DC V / Frequency input), CH B: Rotation signal input (DC V / Pulse input), CH Z: Z-phase signal input (Pulse input)
Measurement itemVoltage, Torque, Rotation, Frequency, Slip, Motor power
DC V (CH A/B)Measurement range: ±1 V/ ±5 V/ ±10 V, Accuracy: ±0.1 % rdg. ±0.1 % f.s.
Frequency (CH A)Effective amplitude range: ±5 V peak, Measurement band: 1 kHz to 100 kHz
Pulse (CH B)Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 1 Hz to 200 kHz
Pulse (CH Z)Detection level: (Low) 0.5 V or less, (High) 2.0 V or more, Measurement band: 0.1 Hz to 1 kHz

 

Write your review

POWER ANALYZER 3390-10

POWER ANALYZER 3390-10

DC, 0.5 Hz to 150 kHz, 3-phase 4-wire, High Precision Power Analyzer for Motor and Inverter Efficiency Analysis

Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy.

Write your review

top