Ready StockAir Quality Meter
Atlas Scientific IXIAN Industrial pH Transmitter #IXIAN-pH
Designed with PLCs in mind, the Atlas Scientific Industrial pH transmitter is a simple to use pH transmitter that gets right to the point, reading pH.
The DIN rail mount and wide operating voltage make it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.
SKU: IXIAN-pH -
Pre-OrderAir Quality Meter
Garmin Power Cable (8-pin) – Power Cable 8 PIN for GPSMAP 585 Plus 800/1000/7×07/7×08/7×10/7×12 Series
Air Quality MeterGarmin Power Cable (8-pin) – Power Cable 8 PIN for GPSMAP 585 Plus 800/1000/7×07/7×08/7×10/7×12 Series
The Garmin 8‑pin Power Cable is a rugged accessory designed to supply reliable power to compatible Garmin chartplotters, fishfinders, and marine GPS units. It ensures a secure connection in demanding marine environments.
SKU: 010-12152-00 -
Pre-OrderAir Quality Meter, CO Meter, CO2 Meter, Humidity Meter
Lutron AQ-9901SD – Air Quality Meter CO2, CO, O2, Humidity, Temp.
Air Quality Meter, CO Meter, CO2 Meter, Humidity MeterLutron AQ-9901SD – Air Quality Meter CO2, CO, O2, Humidity, Temp.
The AQ-9901SD Air Quality Meter provides accurate and reliable measurements of CO2, CO, O2, humidity, dew point, and temperature, with real-time data logging capabilities, making it an essential tool for various industrial and environmental applications.
SKU: L-AQ9901SD -
Ready StockAir Quality Meter
Lutron BVB-8207SD – 4 channels Vibration Recorder
GENERAL SPECIFICATIONS
Circuit
Custom one-chip of microprocessor LSI circuit.
Display
LCD size : 82 mm x 61 mm. * with green color backlight.
Channels
4 channels :
CH1, CH2, CH3, CH4.Measurement
Velocity, Acceleration, Displacement
Function
Acceleration, Velocity : RMS, Peak, Max Hold.
Displacement :
p-p ( peak-peak ), Max Hold p-p.Unit
Measurement
Metric
Imperial
Acceleration
meter/s^2, g
ft/s^2,
Velocity
mm/s, cm/s
inch/s
Displacement
mm
inch
Frequency range
10 Hz to 1 KHz
* Sensitivity relative during thethe frequency range meet ISO 2954 Refer to table 1, page 28
Circuit
Exclusive microcomputer circuit.
Peak Measurement
Acceleration, Velocity :
To measure and update the peak value.Displacement :
To measure and update the peak to peak ( p-p ) value.Max Hold Measurement
Acceleration, Velocity :
To measure and update the max. peak value.Displacement :
To measure and update the max. peak to peak ( p-p ) value.Zero Button
Under Acceleration ( RMS ) measurement, sensor motionless , press Logger Button
( 3-6, Fig. 1 ) > 5 seconds.Max. Hold Reset Button
Under Max. hold measurement, press Logger Button ( 3-6, Fig. 1 ) > 5 seconds.
Datalogger Sampling Time Setting range
Auto
1 second to 3600 seconds
@ Sampling time can set to 1 second,but memory data may loss.
Manual
Push the data logger button once will save data one time. @ Set the sampling time to
0 second.
@ Manual mode, can also select the1 to 99 position ( Location ) no.
Data error no.
≦ 0.1 % no. of total saved data typically.
Memory Card
SD memory card 1 GB to 16 GB.
Advanced setting
- * Set clock time ( Year/Month/Date, Hour/Minute/ Second )
- * Decimal point of SD card setting
- * Auto power OFF management
- * Set beep Sound ON/OFF
- * Set sampling time
- * SD memory card Format
Data Hold
Freeze the display reading.
* Only available for the RMS function.Memory Recall
Maximum & Minimum value.
* Only available for the RMS function.Data Output
RS 232/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.
* Connect the optional USB cable USB-01 will get the USB plug.
Sampling Time of Display
Approx. 1 second.
Operating Temperature and Humidity
0 to 50 °C.
Less than 85% R.H.Power Supply
* Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 8 PCs, or equivalent.
* ADC 9V adapter input. ( AC/DC power adapter is optional ).
Power Current
Normal operation ( w/o SD card save data and LCD Backlight is OFF) :
Approx. DC 12 mA.
When SD card save the data and LCD Backlight is OFF) :
Approx. DC 35 mA.
Weight
Meter : 515 g/ 1.13 LB.
Probe with cable and magnetic base : 99 g/0,22 LB
Dimension
Meter: 203x76x38mm Vibration sensor probe:
Round 16 mm Dia. x 37 mm. Cable length : 1.2 meter.
Accessories Included
- * Instruction manual………………….. 1 PC
- * Vibration sensor set, VB-83 with
cable…………………………………….1 PC
- * Magnetic base…………………………1 PC
- * Hard carrying case………………….. 1 PC
Optional Accessories
* Vibration sensor set with cable, VB-83. * Tip type vibration sensor set, VB-84.
* SD Card
* AC to DC 9V adapter.* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software,SW-U801-WIN.ELECTRICALSPECIFICATIONS (23±5°C)
Acceleration ( RMS, Peak, Max Hold )
Unit
m/s^2
Range
0.5 to 199.9 m/s^2
Resolution
0.1 m/s^2
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
50 m/S^2 ( 160 Hz )
Unit
g @ 1 g = 9.8 m/s^2
Range
0.05 to 20.39 G
Resolution
0.01 G
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
50 m/S^2 ( 160 Hz )
Unit
ft/s^2
Range
2 to 656 ft/s^2
Resolution
1 ft/s^2
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
50 m/S^2 ( 160 Hz )
Remark :
RMS : To measure the true RMS value.
Peak : To measure and update the peak value.
Max. Hold : To measure and update the max. peak value.Velocity ( RMS, Peak, Max Hold )
Unit
mm/s
Range
0.5 to 199.9 mm/s
Resolution
0. 1 mm/s
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
50 mm/s ( 160 Hz )
Unit
cm/s
Range
0.05 to 19.99 cm/s
Resolution
0. 01 cm/s
Accuracy
± ( 5 % + 5 d ) reading @160Hz,80Hz,23± 5°C
Calibration Point
50 mm/s ( 160 Hz )
Unit
inch/s
Range
0.02 to 7.87 inch/s
Resolution
0.01 inch/s
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
50 mm/s ( 160 Hz )
Remark :
RMS : To measure the true RMS value.
Peak : To measure and update the peak value.
Max. Hold : To measure and update the max. peak value.Displacement ( p-p, Max Hold p-p )
Unit
mm
Range
1.999 mm
Resolution
0.001 mm
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
0.141 mm ( 160 Hz )
Unit
inch
Range
0.078 inch
Resolution
0.001 inch
Accuracy
± ( 5 % + 5 d ) reading
@ 160 Hz, 80 Hz, 23 ± 5 °CCalibration Point
0.141 mm ( 160 Hz )
Remark : p-p :
To measure the Peak to Peak value. Max. Hold p-p :
To measure and update the max. Peak to Peak value.
SKU: L-BVB8207SD -
Pre-OrderAir Quality Meter
Lutron CO2-9914SD – CO2 Meter Humidity/Temperature in one probe
The CO2-9914SD Air Quality Meter provides accurate and reliable measurements of carbon dioxide (CO2), humidity, and temperature, with real-time data logging capabilities, making it an essential tool for various industrial, environmental, and indoor air quality applications.
SKU: L-CO29914SD -
Ready StockAir Quality Meter
Lutron CP-3000 – Flexible Current Probe 3000A for DW-6093 DW-6095 DW-6195
The CP-3000 Flexible AC Current Probe is designed to work seamlessly with the DW-6093 and DW-6095 3-Phase Power Analyzers, providing accurate and reliable measurements for various applications in electrical testing, industrial environments, and maintenance.
SKU: L-CP3000 -
Ready StockAir Quality Meter
Lutron CP-6001 – Flexible Current Probe 6000 Amp for DW-6093 DW-6095 DW-6195
The CP-6001 Flexible AC Current Probe is designed to work seamlessly with the DW-6093 and DW-6095 3-Phase Power Analyzers, providing accurate and reliable measurements for various applications in electrical testing, industrial environments, and maintenance.
SKU: L-CP6001 -
Ready Stock
-
Pre-OrderAir Quality Meter
Lutron DL-9602SD – Real Time SD Card Data Logger
The DL-9602SD Set offers accurate and reliable measurements along with real-time data recording capabilities, making it an essential tool for various applications in electrical maintenance, troubleshooting, industrial environments, and quality control.
SKU: L-DL9602SD -
Ready StockAir Quality Meter
Lutron DS-2013SD – Noise Dosimeter with SD Card Data Recorder
The DS-2013SD Noise Dosimeter provides accurate and reliable measurements of sound exposure levels, with real-time data logging capabilities, making it an essential tool for various industrial and environmental noise monitoring applications.
SKU: L-DS2013SD -
Ready StockAir Quality Meter
Lutron EM-1900 – 9 in 1 Environment Meter
The EM-1900 Environmental Meter provides accurate and reliable measurements of air velocity, temperature, humidity, light, air flow, dew point, wet bulb temperature, wind chill, and heat index, making it an essential tool for various industrial, environmental, and HVAC applications.
SKU: L-EM1900 -
Pre-OrderAir Quality Meter
Lutron EMF-810 – Micro Wave Leakage Detector
The EMF-810 Microwave Leakage Detector provides accurate and reliable measurements of electromagnetic field (EMF) values for microwave frequencies, making it an essential tool for various industrial, environmental, and safety applications.