VOLTAGE/CURRENT CALIBRATOR
Model: CC-421

OVERVIEW:
The CC-421 Voltage/Current Calibrator provides accurate and reliable calibration for process devices and signals, making it an essential tool for various industrial applications

FEATURES:
◆ The instruments Powers or Measure a two-wire current loop. Four function provide the quality and accuracy of handheld calibrator:
a. Precision current source
b. Measurement of a current signal
c. Power and measurement of two wire loop.
d. Precision DC mV source
◆ Portable instrument for calibrating process devices and measuring process signals
◆ Adjustable 0-24 mA current source
◆ Adjustable -199.9 mV to +1.99.9 mV DC voltage source
◆ Current calibrator drives loads up to 500 ohms

ACCESSORIES INCLUDED:
◆ Operational manual
◆ Cable with the alligator pairs (red & black), LN-TL421

SKU: L-CC421 Categories: , Brand:
Weight0.5 kg

GENERAL SPECIFICATIONS

Display

LCD display, max. display counts 1999. 13 mm ( 0.5″ ) digit size.

Operating Temperature & Humidity

0°C to 50°C( 32°Fto 122°F). Less than 80% RH.

Function

  1. 1)  Current source
  2. 2)  Current measurement
  3. 3)  Power and current measurement of

    two wire loop

  4. 4)  DC mV source

Power Supply

006P DC 9V, MN1604/PP3 battery or equivalent. Alkaline type or heavy duty type.

Dimension

185 x 78 x 38 mm ( 7.3 x 3.0 x 1.5 inch ).

Weight

265 g/0.58 LB ( including battery ).

Sampling Time

Approx. 0.4 second.

Accessories Included

Operational manual…………………………. 1 PC. Cable with the alligator pairs
( red & black ), LN-TL421…………………. 1 PC.

ELECTRICAL SPECIFICATION ( 23 ± 5 °C)

Current source

Current measurement

Range

Display Resolution

Accuracy

Range

Display Resolution

Accuracy

0 – 19.99 mA

0.01 mA

± ( 0.25 % FS + 1 d )

0 – 19.99 mA

0.01 mA

± ( 0.25 % FS + 1 d )

0 – 24 mA

0.1 mA

± ( 0.5 % FS + 1 d )

0 – 24 mA

0.1 mA

± ( 0.5 % FS + 1 d )

Power and current measurement of two wire loop

DC mV source

Range

Display Resolution

Accuracy

Range

Display Resolution

Accuracy

0 – 19.99 mA

0.01 mA

± ( 0.25 % FS + 1 d )

– 199.9 mV to
+ 199.9 mV

0.1 mV

± ( 0.25 % FS + 1 d )

0 – 24 mA

0.1 mA

± ( 0.5 % FS + 1 d )

* Provides power DC 12V 2 V to the loop and measures current.

* FS : full scale

* Output measured load impedance should > 1 K ohms. * FS : full scale