USB DAQ device with 4 dedicated ±10V, 12-bit  analog inputs, 12 flexible I/O, and 4 dedicated digital I/O. The flexible I/O can be configured as either digital or analog, thus providing up to 16 analog inputs, or up to 16 digital I/O. It also has two 10-bit analog outputs, up to 2 counters, and up to 2 timers.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

Bagikan:

U3-HV vs U3-LV

U3-LVU3-HV
# Low-voltage AINs: 1612
# High-voltage AINs: 0 4
#DIOs 20 16

The U3-HV has the following differences versus the U3-LV:
◆ First 4 flexible I/O are changed to dedicated HV analog inputs.
◆ 4 HV inputs have ±10 volt or -10/+20 volt range.
◆ 12 LV inputs (flexible I/O) still available, for 16 total analog inputs.

OVERVIEW:
The U3 series is a versatile product for measurement and control within simple analog and digital systems. With the option to configure its I/O as either analog or digital, users have flexibility in choosing sensors for their application. Common applications include hobbyist projects, educational programs, industrial control and monitoring, and prototype development

KEY FEATURES:
◆ 12 Flexible I/O (digital input, digital output, or analog input)
◆ Up to 12 analog inputs with 12-bit resolution, 0 to +3.6V
◆ 4 dedicated high voltage analog inputs, -10 to +20V
◆ Up to 16 digital I/O (3.3V logic)
◆ Up to 2 counters (32-bits each)
◆ 2 analog outputs (10-bit, 0-5 volts)
◆ Serial protocols: SPI, I2C
◆ Industrial temperature range (-40° to 85°C)
◆ Up to 2 PWM, quadrature, pulse width
◆ Capable of command/response times less than 1mS
◆ Maximum input stream rate of 50kHz (depending on resolution)

EACH UNIT INCLUDES WITH:
◆ U3-HV
◆ USB cable
◆ Screwdriver

SKU: LJ-U3HV Category: Brand:
Weight0.5 kg

U3 Highlights

Flexible I/O:

The first 16 I/O lines (FIO and EIO ports) on the LabJack U3-LV can be individually configured as digital input, digital output, or analog input. In addition, up to 2 of these lines can be configured as timers, and up to 2 of these lines can be configured as counters. On the U3-HV, the first 4 flexible I/O are replaced with dedicated high-voltage analog inputs.

The first 8 flexible I/O lines (FIO0-FIO7) appear on built-in screw terminals. The other 8 flexible I/O lines (EIO0-EIO7) are available on the DB15 connector.

For more information, see Section 2.5 – Flexible I/O (FIO/EIO) of the U3 Datasheet.

Analog Inputs:

The LabJack U3 has up to 16 analog inputs available on the flexible I/O lines. Single-ended measurements can be taken of any line compared to ground, or differential measurements can be taken of any line to any other line.

Analog input resolution is 12-bits. The range of single-ended low-voltage analog inputs on the U3-LV is typically 0-2.4 volts or 0-3.6 volts, and the range of differential analog inputs is typically ±2.4 volts (pseudobipolar only). For valid measurements, the voltage on every analog input pin, with respect to ground, must be within -0.3 to +3.6 volts.

On the U3-HV, the first 4 flexible I/O are replaced with dedicated high-voltage analog inputs. The input range of these channels is ±10 volts or -10/+20 volts. The remaining 12 flexible I/O are still available as described above, so the U3-HV has 4 high-voltage analog inputs and up to 12 low-voltage analog inputs.

Command/response (software timed) analog input reads typically take 0.6-4.0 ms depending on number of channels and communication configuration. Hardware timed input streaming has a maximum rate that varies with resolution from 2.5 ksamples/s at 12-bits to 50 ksamples/s at about 10-bits.

For more information see the U3 Datasheet. For analog input information see Section 2.6 – AIN and Appendix A. For data rate information see Sections 3.1 – Command/Response and Sections 3.2 – Stream Mode.

Analog Outputs:

The LabJack U3 has 2 analog outputs (DAC0 and DAC1) that are available on the screw terminals. Each analog output can be set to a voltage between 0 and 5 volts with 10-bits of resolution.

The analog outputs are updated in command/response mode, with a typical update time of 0.6-4.0 ms depending on communication configuration. The analog outputs have filters with a 3 dB cutoff around 16 Hz, limiting the frequency of output waveforms to less than that.

For more information see the U3 Datasheet. For analog output information see Section 2.7 – DAC and Appendix A. For data rate information see Section 3.1 – Command/Response.

Digital I/O:

The LabJack U3 has up to 20 digital I/O channels. 16 are available from the flexible I/O lines, and 4 dedicated digital I/O (CIO0-CIO3) are available on the DB15 connector. Each digital line can be individually configured as input, output-high, or output-low. The digital I/O use 3.3-volt logic and are 5 volt tolerant.

Command/response (software timed) reads/writes typically take 0.6-4.0 ms depending on communication configuration. The first 16 digital inputs can also be read in a hardware timed input stream where all 16 inputs count as a single stream channel.

For more information see the U3 Datasheet. For digital I/O information see Section 2.8 – Digital I/O and Appendix A. For data rate information see Section 3.1 – Command/Response and Sections 3.2 – Stream Mode.

Timers:

Up to 2 flexible I/O lines can be configured as timers. The timers are very flexible, providing options such as PWM output, pulse/period timing, pulse counting, and quadrature input.

For more information see the U3 Datasheet. For timers information see Section 2.9 – Timers/Counters and Appendix A.

Counters:

Up to 2 flexible I/O lines can be configured as 32-bit counters.

For more information see the U3 Datasheet. For counters information see Section 2.9 – Timers/Counters and Appendix A.

I/O Protection:

All I/O lines on the U3 are protected against minor overvoltages. The FIO lines can withstand continuous voltages of up to ±10 volts, while the EIO/CIO lines withstand continuous voltages of up to ±6 volts.

High Channel Count Applications:

By using USB hubs, many LabJacks can be interfaced to a single PC, providing an inexpensive solution for high channel count applications.

U3-HV vs U3-LV

U3-LVU3-HV
# Low-voltage AINs: 1612
# High-voltage AINs: 0 4
#DIOs 20 16

The U3-HV has the following differences versus the U3-LV:

  • First 4 flexible I/O are changed to dedicated HV analog inputs.
  • 4 HV inputs have ±10 volt or -10/+20 volt range.
  • 12 LV inputs (flexible I/O) still available, for 16 total analog inputs.

OEM Versions

The U3-LV-OEM or U3-HV-OEM includes the board only without the enclosure and without most through-hole components. See Section 2.12 of the U3 Datasheet for more information.

Analog Input U3-HV (High-Voltage) Version:

Same features as the LV version except:

  • First 4 Flexible I/O are Changed to Dedicated HV Analog Inputs.
  • 4 HV Inputs have ±10 Volt or -10/+20 Volt Range.
  • 12 LV Inputs (Flexible I/O) Still Available, for 16 Total Analog Inputs.

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “LabJack U3-HV – USB Multifunction Data Acquisition with 12 Flexible I/O (DAQ)”

There are no reviews yet.

SHOPPING CART

close
Hi, There!

How can I help you?

Chat

Select at least 2 products
to compare