Lutron PM-1064SD – Air Quality Monitor / Particulate Matter (PM2.5, CO2, %RH, Temp., Barometer)

Availability:

5 in stock


The PM-1064SD Air Quality Monitor/Recorder provides accurate and reliable measurements of PM2.5, CO2, humidity, temperature, and barometric pressure, with real-time data logging capabilities, making it an essential tool for various industrial, environmental, and HVAC applications.

Status Barang: Ready

Kondisi: Baru

Minimal Order: 1 pcs

$472.57

5 in stock

Bagikan:

AIR QUALITY MONITOR/RECORDER (PM2.5, CO2, %RH, Temp., Barometer)
Model: PM-1064SD

OVERVIEW:
Monitoring air pollutant source from dust, petrochemical industry, steel-making plant, thermal power plant, restaurant, smoke, burning plants, driving automobiles. The meter is a real-time air quality monitor instrument used to monitor the concentration of PM2.5, humidity and temperature in the indoor environment. What is PM? PM is short for “particulate matter”. It refers to particles found in the air, including dust, dirt, soot, smoke, and liquid droplets. Particles can be suspended in the air for long periods of time. Many man-made and natural sources emit PM directly or emit other pollutants that react in the atmosphere to form PM. These solid and liquid particles come in a wide range of sizes. Some particles are large or dark enough to be seen – like soot or smoke. Others are so small that individually, they can only be detected with an electron microscope. What is the difference between PM2.5 amp; PM10? PM10 refers to particles with diameters that are less than or equal to 10 microns in size (a micron, or micrometer, is one-millionth of a meter), or about 1/7 the diameter of a human hair. PM2.5, also called “fine particulates,” consists of particles with diameters that are less than or equal to 2.5 microns in size. That’s about 1/30 the diameter of a human hair. PM2.5 is a more serious health concern than PM10, since smaller particles can travel more deeply into our lungs and affect your health.

FEATURES:
◆ PM2.5: 0 to 250 μg/m^3
◆ Humidity: 5 to 95 %RH
◆ Temp: 0 to 50 °C,°C/°F
◆ CO2: 0 to 10,000 ppm
◆ Barometer: 10 to 1100 hPa, mmHg, inHg.

EACH UNIT INCLUDES WITH:
◆ Instruction manual
◆ AC to DC 9V power adapter

OPTIONAL ACCESSORIES:
◆ SD Card
◆ USB Cable, USB-01
◆ RS232 Cable, UPCB-02
◆ Data Acquisition Software, SW-U801-WIN

SKU: L-PM1064SD Category: Brand:
Weight1 kg

SPECIFICATIONS

Circuit

Custom single-chip microprocessor LSI circuit.

Display

LCD Size: 2.18 X 2.87″ (55.4 X 72.9 mm). Dot matrix backlit LCD (128 X 240 pixels).

Measurement

PM2.5 : 0 to 250 μ g/m^3, Humidity : 5 to 95 %RH, CO2 : 0 to 10,000 ppm, Barometer : 10 to 1100 hPa, Temperature : 0 to 50 °C,°C/°F.

Over-range

* LCD display show ” OL “..
* The data save into the Micro SD card will show ” 999 ”

(overleap the decimal point).

Data Hold

Freezes displayed reading.

Memory Recall

Maximum & Minimum value.

Data Recording

SD memory card ( 1 GB to 32 GB ).

Sampling Time

Approx. 1 second.

Datalogger

  • *  Real time data logger, saved the data into Micro SD memory card and down load the all the measured value with the time information ( year/month/date/ hour/minute/second ) down load to the Excel.
  • *  Sampling time for data logger :
    Auto: 2 seconds to 3600 seconds.
    Manual: Push the data logger button once will save data one time.

    @ Set the sampling time to 0 second.

    @ Manual mode, can also select the 1 to 99 position.

  • *  When the system detects micro SD format does not match

    with the Machine that will be mandatory for reformatting to

    ensure that data records can be normal.

  • *  Data error no. : ≦ 0.1% no. of total saved data typically.

Data Output USB/RS232

* Computer interface.
* Connect the optional USB cable USB-01 will get the USB plug..
* Connect the optional RS232 cable UPCB-02 will get the RS232 plug.

Operating temperature

0 to 50°C ( 32 to 122°F ).

Operating humidity

Less than 80% R.H..

Power Supply

* DC1.5V,AA(UM-3)BatteryX6PCs (Alkaline or heavy-duty battery).

* AC to DC 9V power adapter..

Power consumption

DC 135 mA approximately.
Backlight ON approximately DC 150 mA.

Weight

385 g/0.85 LB.

Dimension

164 x 93 x 72 mm ( 6.5 x 3.7 x 2.8 inch ).
* Dimension is for the meter only ( without terminals ).

Accessories included

* Instruction manual……………………………………………………. 1 PC
* AC to DC 9V power adapter…………………………………………. 1 PC

Optional Accessories

* SD card.
* USB cable, USB-01.
* RS232 cable, UPCB-02.
* Data Acquisition software, SW-U801-WIN, SW-E802.

Electrical SPECIFICATIONS (23 ± 5 °C)

PM2.5 ( Particulate matter )

Range

Resolution

Accuracy

0 to 250 μ g/m^3

1 μ g/m^3

± (10%reading± 20μ g/m^3)

Humidity

Range

Resolution

Accuracy

5 % to 95 %RH

0.1 %RH

<70%RH:± 3%RH

Temperature

Range

Resolution

Accuracy

0.0 °C to 50.0 °C

0.1 °C

± 0.8 °C

32.0 °F to 122.0 °F

0.1 °F

± 1.5 °F

CO2 (Carbon dioxide)

Range

Resolution

Accuracy

0 to 10000 ppm

1 ppm

± 40 ppm, ≦ 1000 ppm

± (50ppm+3%ofreading) > 1000 ppm ≦ 3000 ppm

± (50 ppm + 5% of reading) > 3000 ppm ≦ 10000 ppm

Repeatability:
± 20 ppm
> 3000 ppm ≦ 10000 ppm

Barometric pressure ( Barometer )

Unit

Range

Resolution Accuracy

hPa

10.0 to 999.9 1000 to 1100

0.1 hPa 1 hPa

± 1.5 hPa ± 2 hPa

mmHg

7.5 to 825.0

0.1mmHg

± 1.2 mmHg

inHg

0.29 to 32.48

0.01inHg

± 0.05 inHg

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Lutron PM-1064SD – Air Quality Monitor / Particulate Matter (PM2.5, CO2, %RH, Temp., Barometer)”