{"id":6824,"date":"2025-12-15T09:48:07","date_gmt":"2025-12-15T09:48:07","guid":{"rendered":"https:\/\/dutapersada.co.id\/?post_type=product&#038;p=6824"},"modified":"2026-02-13T10:03:31","modified_gmt":"2026-02-13T10:03:31","slug":"lutron-bvb-8207sd-4-channels-vibration-recorder","status":"publish","type":"product","link":"https:\/\/dutapersada.co.id\/en\/product\/lutron-bvb-8207sd-4-channels-vibration-recorder\/","title":{"rendered":"Lutron BVB-8207SD &#8211; 4 channels Vibration Recorder"},"content":{"rendered":"<p>4 channels VIBRATION RECORDER<br \/>\nModel: BVB-8207SD<\/p>\n<p>OVERVIEW:<br \/>\nThe BVB-8207SD 4-Channel Vibration Meter provides accurate and reliable measurements of vibration across four channels with real-time data logging capabilities, making it an essential tool for industrial vibration monitoring and control.<\/p>\n<p>FEATURES:<br \/>\n\u25c6 4 channels vibration recorder, use SD card to save the data along with time information, paperless.<br \/>\n\u25c6 Real time data logger, save the measuring data along the time information (year, month, date,hour, minute, second) into the SD memory card and can be downloaded to the Excel, extra software is no need.<br \/>\n\u25c6 Show CH1 to CH4 vibration values in the same LCD.<br \/>\n\u25c6 Time information: Year, Month, Date, Hour, Minute and Second.<br \/>\n\u25c6 Sampling setting: 1 to 3600 seconds.<br \/>\n\u25c6 Function: Acceleration\/Velocity\/Displacement.<br \/>\n\u25c6 Acceleration : 200 m\/s2.<br \/>\n\u25c6 Velocity : 200 mm\/s.<br \/>\n\u25c6 Displacement (p-p) : 2 mm.<br \/>\n\u25c6 Max hold, peak value, data hold, Max.\/Min..<br \/>\n\u25c6 RS232\/USB computer interface.<br \/>\n\u25c6 Memory card size: 1 GB to 16 GB (NOT INCLUDED)<br \/>\n\u25c6 Supper large LCD with backlight, easy reading.<br \/>\n\u25c6 Data hold, Record (Max., Min.).<br \/>\n\u25c6 RS232\/USB computer interface.<br \/>\n\u25c6 Include 1 PC sensor vibration set, VB-83.<br \/>\n\u25c6 Extra vibration sensor set, VB-83 can be ordered. When changing the VB-83, it is not necessary to make the new calibration again.<br \/>\n\u25c6 DC 1.5V (UM-3\/AA) x 8 PCs or DC 9V adapter in.<br \/>\n\u25c6 Patented.<\/p>\n<p>ACCESSORIES INCLUDED:<br \/>\n\u25c6 Instruction manual<br \/>\n\u25c6 Vibration sensor with cable, VB-83<br \/>\n\u25c6 Magnetic base<br \/>\n\u25c6 Hard Carrying Case<\/p>\n<p>OPTIONAL ACCESSORIES:<br \/>\n\u25c6 SD Card (1 GB to 16 GB)<br \/>\n\u25c6 AC to DC 9V Adapter<br \/>\n\u25c6 USB Cable (USB-01)<br \/>\n\u25c6 RS232 Cable (UPCB-02)<br \/>\n\u25c6 Data Acquisition Software (SW-U801-WIN)<br \/>\n\u25c6 Additional Vibration Sensors (VB-83)<\/p>\n","protected":false},"excerpt":{"rendered":"<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>GENERAL SPECIFICATIONS<\/p>\n<\/div>\n<\/div>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Circuit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Custom one-chip of microprocessor LSI circuit.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Display<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>LCD size : 82 mm x 61 mm. * with green color backlight.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Channels<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>4 channels :<br \/>\nCH1, CH2, CH3, CH4.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Measurement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Velocity, Acceleration, Displacement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Function<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Acceleration, Velocity : RMS, Peak, Max Hold.<\/p>\n<p>Displacement :<br \/>\np-p ( peak-peak ), Max Hold p-p.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"4\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Measurement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Metric<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Imperial<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Acceleration<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>meter\/s^2, g<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>ft\/s^2,<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Velocity<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>mm\/s, cm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>inch\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Displacement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>mm<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>inch<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Frequency range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>10 Hz to 1 KHz<br \/>\n* Sensitivity relative during the<\/p>\n<p>the frequency range meet ISO 2954 Refer to table 1, page 28<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Circuit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Exclusive microcomputer circuit.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Peak Measurement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Acceleration, Velocity :<br \/>\nTo measure and update the peak value.<\/p>\n<p>Displacement :<br \/>\nTo measure and update the peak to peak ( p-p ) value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Max Hold Measurement<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Acceleration, Velocity :<br \/>\nTo measure and update the max. peak value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Displacement :<br \/>\nTo measure and update the max. peak to peak ( p-p ) value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Zero Button<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Under Acceleration ( RMS ) measurement, sensor motionless , press Logger Button<br \/>\n( 3-6, Fig. 1 ) &gt; 5 seconds.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Max. Hold Reset Button<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Under Max. hold measurement, press Logger Button ( 3-6, Fig. 1 ) &gt; 5 seconds.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Datalogger Sampling Time Setting range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Auto<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"3\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>1 second to 3600 seconds<br \/>\n@ Sampling time can set to 1 second,<\/p>\n<p>but memory data may loss.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Manual<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"3\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Push the data logger button once will save data one time. @ Set the sampling time to<\/p>\n<p>0 second.<br \/>\n@ Manual mode, can also select the<\/p>\n<p>1 to 99 position ( Location ) no.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Data error no.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u2266 0.1 % no. of total saved data typically.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Memory Card<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>SD memory card 1 GB to 16 GB.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Advanced setting<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ul>\n<li>* \u00a0Set clock time ( Year\/Month\/Date, Hour\/Minute\/ Second )<\/li>\n<li>* \u00a0Decimal point of SD card setting<\/li>\n<li>* \u00a0Auto power OFF management<\/li>\n<li>* \u00a0Set beep Sound ON\/OFF<\/li>\n<li>* \u00a0Set sampling time<\/li>\n<li>* \u00a0SD memory card Format<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Data Hold<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Freeze the display reading.<br \/>\n* Only available for the RMS function.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Memory Recall<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Maximum &amp; Minimum value.<br \/>\n* Only available for the RMS function.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Data Output<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td colspan=\"4\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>RS 232\/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.<\/p>\n<p>* Connect the optional USB cable USB-01 will get the USB plug.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"page\" title=\"Page 2\">\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Sampling Time of Display<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Approx. 1 second.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Operating Temperature and Humidity<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0 to 50 \u00b0C.<br \/>\nLess than 85% R.H.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Power Supply<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>* Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 8 PCs, or equivalent.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>* ADC 9V adapter input. ( AC\/DC power adapter is optional ).<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Power Current<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Normal operation ( w\/o SD card save data and LCD Backlight is OFF) :<\/p>\n<p>Approx. DC 12 mA.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>When SD card save the data and LCD Backlight is OFF) :<\/p>\n<p>Approx. DC 35 mA.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Weight<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Meter : 515 g\/ 1.13 LB.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Probe with cable and magnetic base : 99 g\/0,22 LB<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Dimension<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Meter: 203x76x38mm Vibration sensor probe:<\/p>\n<p>Round 16 mm Dia. x 37 mm. Cable length : 1.2 meter.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accessories Included<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<ul>\n<li>* \u00a0Instruction manual&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.. 1 PC<\/li>\n<li>* \u00a0Vibration sensor set, VB-83 with\n<p>cable&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.1 PC<\/li>\n<li>* \u00a0Magnetic base&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;1 PC<\/li>\n<li>* \u00a0Hard carrying case&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;&#8230;.. 1 PC<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Optional Accessories<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>* Vibration sensor set with cable, VB-83. * Tip type vibration sensor set, VB-84.<br \/>\n* SD Card<br \/>\n* AC to DC 9V adapter.<\/p>\n<p>* USB cable, USB-01.<br \/>\n* RS232 cable, UPCB-02.<br \/>\n* Data Acquisition software,SW-U801-WIN.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>ELECTRICALSPECIFICATIONS (23\u00b15\u00b0C)<\/p>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Acceleration ( RMS, Peak, Max Hold )<\/p>\n<div class=\"page\" title=\"Page 2\">\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>m\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.5 to 199.9 m\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.1 m\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 m\/S^2 ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>g @ 1 g = 9.8 m\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.05 to 20.39 G<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.01 G<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 m\/S^2 ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"page\" title=\"Page 2\">\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>ft\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>2 to 656 ft\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>1 ft\/s^2<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 m\/S^2 ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Remark :<br \/>\nRMS : To measure the true RMS value.<br \/>\nPeak : To measure and update the peak value.<br \/>\nMax. Hold : To measure and update the max. peak value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Velocity ( RMS, Peak, Max Hold )<\/p>\n<div class=\"page\" title=\"Page 2\">\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>mm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.5 to 199.9 mm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0. 1 mm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 mm\/s ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>cm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.05 to 19.99 cm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0. 01 cm\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading @160Hz,80Hz,23\u00b1 5\u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 mm\/s ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>inch\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.02 to 7.87 inch\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.01 inch\/s<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>50 mm\/s ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Remark :<br \/>\nRMS : To measure the true RMS value.<br \/>\nPeak : To measure and update the peak value.<br \/>\nMax. Hold : To measure and update the max. peak value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"page\" title=\"Page 2\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Displacement ( p-p, Max Hold p-p )<\/p>\n<\/div>\n<\/div>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>mm<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>1.999 mm<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.001 mm<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.141 mm ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<tbody>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Unit<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>inch<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Range<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.078 inch<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Resolution<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.001 inch<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Accuracy<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>\u00b1 ( 5 % + 5 d ) reading<br \/>\n@ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Calibration Point<\/p>\n<\/div>\n<\/div>\n<\/td>\n<td>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>0.141 mm ( 160 Hz )<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>Remark : p-p :<\/p>\n<p>To measure the Peak to Peak value. Max. Hold p-p :<\/p>\n<\/div>\n<\/div>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>To measure and update the max. Peak to Peak value.<\/p>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"featured_media":6825,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[244],"product_cat":[319],"product_tag":[],"class_list":{"0":"post-6824","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-lutron","7":"product_cat-air-quality-meter-measuring-instruments","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT\" \/>\n<meta property=\"og:description\" content=\"GENERAL SPECIFICATIONS           Circuit        Custom one-chip of microprocessor LSI circuit.          Display        LCD size : 82 mm x 61 mm. * with green color backlight.          Channels        4 channels : CH1, CH2, CH3, CH4.          Measurement        Velocity, Acceleration, Displacement          Function        Acceleration, Velocity : RMS, Peak, Max Hold.  Displacement : p-p ( peak-peak ), Max Hold p-p.          Unit        Measurement        Metric        Imperial          Acceleration        meter\/s^2, g        ft\/s^2,          Velocity        mm\/s, cm\/s        inch\/s          Displacement        mm        inch          Frequency range        10 Hz to 1 KHz * Sensitivity relative during the  the frequency range meet ISO 2954 Refer to table 1, page 28          Circuit        Exclusive microcomputer circuit.          Peak Measurement        Acceleration, Velocity : To measure and update the peak value.  Displacement : To measure and update the peak to peak ( p-p ) value.          Max Hold Measurement        Acceleration, Velocity : To measure and update the max. peak value.          Displacement : To measure and update the max. peak to peak ( p-p ) value.          Zero Button        Under Acceleration ( RMS ) measurement, sensor motionless , press Logger Button ( 3-6, Fig. 1 ) &gt; 5 seconds.          Max. Hold Reset Button        Under Max. hold measurement, press Logger Button ( 3-6, Fig. 1 ) &gt; 5 seconds.          Datalogger Sampling Time Setting range        Auto        1 second to 3600 seconds @ Sampling time can set to 1 second,  but memory data may loss.          Manual        Push the data logger button once will save data one time. @ Set the sampling time to  0 second. @ Manual mode, can also select the  1 to 99 position ( Location ) no.          Data error no.        \u2266 0.1 % no. of total saved data typically.          Memory Card        SD memory card 1 GB to 16 GB.          Advanced setting         * \u00a0Set clock time ( Year\/Month\/Date, Hour\/Minute\/ Second )  * \u00a0Decimal point of SD card setting  * \u00a0Auto power OFF management  * \u00a0Set beep Sound ON\/OFF  * \u00a0Set sampling time  * \u00a0SD memory card Format          Data Hold        Freeze the display reading. * Only available for the RMS function.          Memory Recall        Maximum &amp; Minimum value. * Only available for the RMS function.          Data Output        RS 232\/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.  * Connect the optional USB cable USB-01 will get the USB plug.               Sampling Time of Display        Approx. 1 second.          Operating Temperature and Humidity        0 to 50 \u00b0C. Less than 85% R.H.          Power Supply        * Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 8 PCs, or equivalent.          * ADC 9V adapter input. ( AC\/DC power adapter is optional ).          Power Current        Normal operation ( w\/o SD card save data and LCD Backlight is OFF) :  Approx. DC 12 mA.          When SD card save the data and LCD Backlight is OFF) :  Approx. DC 35 mA.          Weight        Meter : 515 g\/ 1.13 LB.          Probe with cable and magnetic base : 99 g\/0,22 LB          Dimension        Meter: 203x76x38mm Vibration sensor probe:  Round 16 mm Dia. x 37 mm. Cable length : 1.2 meter.          Accessories Included         * \u00a0Instruction manual....................... 1 PC  * \u00a0Vibration sensor set, VB-83 with  cable...........................................1 PC  * \u00a0Magnetic base..............................1 PC  * \u00a0Hard carrying case....................... 1 PC          Optional Accessories        * Vibration sensor set with cable, VB-83. * Tip type vibration sensor set, VB-84. * SD Card * AC to DC 9V adapter.  * USB cable, USB-01. * RS232 cable, UPCB-02. * Data Acquisition software,SW-U801-WIN.           ELECTRICALSPECIFICATIONS (23\u00b15\u00b0C)     Acceleration ( RMS, Peak, Max Hold )         Unit        m\/s^2          Range        0.5 to 199.9 m\/s^2          Resolution        0.1 m\/s^2          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )              Unit        g @ 1 g = 9.8 m\/s^2          Range        0.05 to 20.39 G          Resolution        0.01 G          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )               Unit        ft\/s^2          Range        2 to 656 ft\/s^2          Resolution        1 ft\/s^2          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )          Remark : RMS : To measure the true RMS value. Peak : To measure and update the peak value. Max. Hold : To measure and update the max. peak value.           Velocity ( RMS, Peak, Max Hold )         Unit        mm\/s          Range        0.5 to 199.9 mm\/s          Resolution        0. 1 mm\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 mm\/s ( 160 Hz )              Unit        cm\/s          Range        0.05 to 19.99 cm\/s          Resolution        0. 01 cm\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @160Hz,80Hz,23\u00b1 5\u00b0C          Calibration Point        50 mm\/s ( 160 Hz )              Unit        inch\/s          Range        0.02 to 7.87 inch\/s          Resolution        0.01 inch\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 mm\/s ( 160 Hz )          Remark : RMS : To measure the true RMS value. Peak : To measure and update the peak value. Max. Hold : To measure and update the max. peak value.           Displacement ( p-p, Max Hold p-p )           Unit        mm          Range        1.999 mm          Resolution        0.001 mm          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        0.141 mm ( 160 Hz )              Unit        inch          Range        0.078 inch          Resolution        0.001 inch          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        0.141 mm ( 160 Hz )          Remark : p-p :  To measure the Peak to Peak value. Max. Hold p-p :       To measure and update the max. Peak to Peak value.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/\" \/>\n<meta property=\"og:site_name\" content=\"DUTA PERSADA INSTRUMENT\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-13T10:03:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/12\/bvb8207sd_b.png\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/\",\"url\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/\",\"name\":\"Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/dutapersada.co.id\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/bvb8207sd_b.png\",\"datePublished\":\"2025-12-15T09:48:07+00:00\",\"dateModified\":\"2026-02-13T10:03:31+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/#primaryimage\",\"url\":\"https:\\\/\\\/dutapersada.co.id\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/bvb8207sd_b.png\",\"contentUrl\":\"https:\\\/\\\/dutapersada.co.id\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/bvb8207sd_b.png\",\"width\":700,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/produk\\\/lutron-bvb-8207sd-4-channels-vibration-recorder\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/dutapersada.co.id\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/dutapersada.co.id\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Lutron BVB-8207SD &#8211; 4 channels Vibration Recorder\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#website\",\"url\":\"https:\\\/\\\/dutapersada.co.id\\\/\",\"name\":\"DUTA PERSADA INSTRUMENT\",\"description\":\"Specialized Electronic Test &amp; Measuring Instruments, dan sudah berdiri sejak tahun 1994.\",\"publisher\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dutapersada.co.id\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#organization\",\"name\":\"DUTA PERSADA INSTRUMENT\",\"url\":\"https:\\\/\\\/dutapersada.co.id\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/dutapersada.co.id\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/Frame-1000004702.png\",\"contentUrl\":\"https:\\\/\\\/dutapersada.co.id\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/Frame-1000004702.png\",\"width\":1820,\"height\":396,\"caption\":\"DUTA PERSADA INSTRUMENT\"},\"image\":{\"@id\":\"https:\\\/\\\/dutapersada.co.id\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/","og_locale":"en_US","og_type":"article","og_title":"Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT","og_description":"GENERAL SPECIFICATIONS           Circuit        Custom one-chip of microprocessor LSI circuit.          Display        LCD size : 82 mm x 61 mm. * with green color backlight.          Channels        4 channels : CH1, CH2, CH3, CH4.          Measurement        Velocity, Acceleration, Displacement          Function        Acceleration, Velocity : RMS, Peak, Max Hold.  Displacement : p-p ( peak-peak ), Max Hold p-p.          Unit        Measurement        Metric        Imperial          Acceleration        meter\/s^2, g        ft\/s^2,          Velocity        mm\/s, cm\/s        inch\/s          Displacement        mm        inch          Frequency range        10 Hz to 1 KHz * Sensitivity relative during the  the frequency range meet ISO 2954 Refer to table 1, page 28          Circuit        Exclusive microcomputer circuit.          Peak Measurement        Acceleration, Velocity : To measure and update the peak value.  Displacement : To measure and update the peak to peak ( p-p ) value.          Max Hold Measurement        Acceleration, Velocity : To measure and update the max. peak value.          Displacement : To measure and update the max. peak to peak ( p-p ) value.          Zero Button        Under Acceleration ( RMS ) measurement, sensor motionless , press Logger Button ( 3-6, Fig. 1 ) &gt; 5 seconds.          Max. Hold Reset Button        Under Max. hold measurement, press Logger Button ( 3-6, Fig. 1 ) &gt; 5 seconds.          Datalogger Sampling Time Setting range        Auto        1 second to 3600 seconds @ Sampling time can set to 1 second,  but memory data may loss.          Manual        Push the data logger button once will save data one time. @ Set the sampling time to  0 second. @ Manual mode, can also select the  1 to 99 position ( Location ) no.          Data error no.        \u2266 0.1 % no. of total saved data typically.          Memory Card        SD memory card 1 GB to 16 GB.          Advanced setting         * \u00a0Set clock time ( Year\/Month\/Date, Hour\/Minute\/ Second )  * \u00a0Decimal point of SD card setting  * \u00a0Auto power OFF management  * \u00a0Set beep Sound ON\/OFF  * \u00a0Set sampling time  * \u00a0SD memory card Format          Data Hold        Freeze the display reading. * Only available for the RMS function.          Memory Recall        Maximum &amp; Minimum value. * Only available for the RMS function.          Data Output        RS 232\/USB PC computer interface. * Connect the optional RS232 cable UPCB-02 will get the RS232 plug.  * Connect the optional USB cable USB-01 will get the USB plug.               Sampling Time of Display        Approx. 1 second.          Operating Temperature and Humidity        0 to 50 \u00b0C. Less than 85% R.H.          Power Supply        * Alkaline or heavy duty DC 1.5 V battery ( UM3, AA ) x 8 PCs, or equivalent.          * ADC 9V adapter input. ( AC\/DC power adapter is optional ).          Power Current        Normal operation ( w\/o SD card save data and LCD Backlight is OFF) :  Approx. DC 12 mA.          When SD card save the data and LCD Backlight is OFF) :  Approx. DC 35 mA.          Weight        Meter : 515 g\/ 1.13 LB.          Probe with cable and magnetic base : 99 g\/0,22 LB          Dimension        Meter: 203x76x38mm Vibration sensor probe:  Round 16 mm Dia. x 37 mm. Cable length : 1.2 meter.          Accessories Included         * \u00a0Instruction manual....................... 1 PC  * \u00a0Vibration sensor set, VB-83 with  cable...........................................1 PC  * \u00a0Magnetic base..............................1 PC  * \u00a0Hard carrying case....................... 1 PC          Optional Accessories        * Vibration sensor set with cable, VB-83. * Tip type vibration sensor set, VB-84. * SD Card * AC to DC 9V adapter.  * USB cable, USB-01. * RS232 cable, UPCB-02. * Data Acquisition software,SW-U801-WIN.           ELECTRICALSPECIFICATIONS (23\u00b15\u00b0C)     Acceleration ( RMS, Peak, Max Hold )         Unit        m\/s^2          Range        0.5 to 199.9 m\/s^2          Resolution        0.1 m\/s^2          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )              Unit        g @ 1 g = 9.8 m\/s^2          Range        0.05 to 20.39 G          Resolution        0.01 G          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )               Unit        ft\/s^2          Range        2 to 656 ft\/s^2          Resolution        1 ft\/s^2          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 m\/S^2 ( 160 Hz )          Remark : RMS : To measure the true RMS value. Peak : To measure and update the peak value. Max. Hold : To measure and update the max. peak value.           Velocity ( RMS, Peak, Max Hold )         Unit        mm\/s          Range        0.5 to 199.9 mm\/s          Resolution        0. 1 mm\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 mm\/s ( 160 Hz )              Unit        cm\/s          Range        0.05 to 19.99 cm\/s          Resolution        0. 01 cm\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @160Hz,80Hz,23\u00b1 5\u00b0C          Calibration Point        50 mm\/s ( 160 Hz )              Unit        inch\/s          Range        0.02 to 7.87 inch\/s          Resolution        0.01 inch\/s          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        50 mm\/s ( 160 Hz )          Remark : RMS : To measure the true RMS value. Peak : To measure and update the peak value. Max. Hold : To measure and update the max. peak value.           Displacement ( p-p, Max Hold p-p )           Unit        mm          Range        1.999 mm          Resolution        0.001 mm          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        0.141 mm ( 160 Hz )              Unit        inch          Range        0.078 inch          Resolution        0.001 inch          Accuracy        \u00b1 ( 5 % + 5 d ) reading @ 160 Hz, 80 Hz, 23 \u00b1 5 \u00b0C          Calibration Point        0.141 mm ( 160 Hz )          Remark : p-p :  To measure the Peak to Peak value. Max. Hold p-p :       To measure and update the max. Peak to Peak value.","og_url":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/","og_site_name":"DUTA PERSADA INSTRUMENT","article_modified_time":"2026-02-13T10:03:31+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/12\/bvb8207sd_b.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/","url":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/","name":"Lutron BVB-8207SD - 4 channels Vibration Recorder - DUTA PERSADA INSTRUMENT","isPartOf":{"@id":"https:\/\/dutapersada.co.id\/#website"},"primaryImageOfPage":{"@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/#primaryimage"},"image":{"@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/#primaryimage"},"thumbnailUrl":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/12\/bvb8207sd_b.png","datePublished":"2025-12-15T09:48:07+00:00","dateModified":"2026-02-13T10:03:31+00:00","breadcrumb":{"@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/#primaryimage","url":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/12\/bvb8207sd_b.png","contentUrl":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/12\/bvb8207sd_b.png","width":700,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/dutapersada.co.id\/produk\/lutron-bvb-8207sd-4-channels-vibration-recorder\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/dutapersada.co.id\/en\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/dutapersada.co.id\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Lutron BVB-8207SD &#8211; 4 channels Vibration Recorder"}]},{"@type":"WebSite","@id":"https:\/\/dutapersada.co.id\/#website","url":"https:\/\/dutapersada.co.id\/","name":"DUTA PERSADA INSTRUMENT","description":"Specialized Electronic Test &amp; Measuring Instruments, dan sudah berdiri sejak tahun 1994.","publisher":{"@id":"https:\/\/dutapersada.co.id\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dutapersada.co.id\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/dutapersada.co.id\/#organization","name":"DUTA PERSADA INSTRUMENT","url":"https:\/\/dutapersada.co.id\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/dutapersada.co.id\/#\/schema\/logo\/image\/","url":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/07\/Frame-1000004702.png","contentUrl":"https:\/\/dutapersada.co.id\/wp-content\/uploads\/2025\/07\/Frame-1000004702.png","width":1820,"height":396,"caption":"DUTA PERSADA INSTRUMENT"},"image":{"@id":"https:\/\/dutapersada.co.id\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/product\/6824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/comments?post=6824"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/media\/6825"}],"wp:attachment":[{"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/media?parent=6824"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/product_brand?post=6824"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/product_cat?post=6824"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/dutapersada.co.id\/en\/wp-json\/wp\/v2\/product_tag?post=6824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}