KYOWA DPM-951A,952A
One Channel
Strong Against Inverter Noise, Easy Operation
KYOWA DPM-951A, 952A
Call 022 7106162
One Channel
Strong Against Inverter Noise, Easy Operation
KYOWA DPM-951A, 952A
Call 022 7106162
Model | Frequency response range | SN Ratio |
---|---|---|
DPM-951A | DC to 2.0kHz | 58dBp-p or more |
DPM-952A | DC to 5kHz | 53dBp-p or more |
(BV=2Vrms,bridge resistance 120Ω,LPF=FLAT 10.00V output with)1000μm/m input
Measuring target | Strain gage, Strain gage transducers | ||||
No. of measuring channels | 1 channel/unit | ||||
Applicable bridge resistance | 60 to 1000Ω | ||||
Gage factor | 2.00 fixed | ||||
Bridge power voltage | 2V rms, 0.5V rms, selectable | ||||
Balance adjustment range
| Resistance: Within ±2%(±10000μm/m) | ||||
Capacitance: Within 2000 pF | |||||
Carrier Frequency | 5kHz (DPM-951A) | ||||
12kHz (DPM-952A) | |||||
Balance adjustment method | Resistance : True electron auto-balance method | ||||
Accuracy : Within±0.5μm/m | |||||
Storage : Written into nonvolatile memor | |||||
Capacitance : CST (Auto-tracking) method | |||||
Nonlinearity | Within ±0.1%FS | ||||
Output impedance | Approx. 2Ω | ||||
Reference equivalent strain(CAL) | ±(1 to 9999μm/m) | ||||
Setting CAL switch (4-digital switch) | |||||
Accuracy: Within ±(0.5% + 0.5μm/m) | |||||
Sensitivity adjustment | CAL switch and VOLTAGE OUT switch Amplifier | ||||
sensitivity is set in combination with CAL and | |||||
VOLTAGE OUT switches (4-digit digital switches) | |||||
VOLTAGE OUTスイッチ範囲:1.00~10.00Vまでの0.01Vステップ | |||||
CAL switch range: 100 to 9999 μm/m by 1μm/m step | |||||
VOLTAGE OUT switch range: 1.00 to 10.00 by 0.01V step | |||||
Accuracy | Within ±0.5% | ||||
Range | X200 to X20000 | ||||
Fine sensitivity control | Range: 1 to 1/2.5 | ||||
Low-pass filter | Transfer characteristic: 2-pole Butterworth | ||||
Cutoff frequency | 6 steps of 10,30,100,300Hz,1kHz and FLAT Cutoff | ||||
Accuracy | -3dB ±1dB | ||||
Attenuation
| -12dB ±1dB/oct. (except when the low- | ||||
pass filter of DPM-951A is set to 1kHz) | |||||
High-pass filter | Cutoff frequency: 2 steps of 0.2Hz and off | ||||
Output | OUTPUT A : ±10V (load resistance 5kΩ or more | ||||
OUTPUT B : ±10V (load resistance 5kΩ or more) | |||||
Stability | Temperature Zero point | Zero point : ±0.1μm/m/℃ | |||
Sensitivity | ±0.05%/℃ | ||||
Time | Zero point : ±0.5μm/m/24h | ||||
Sensitivity : ±0.3%/24h | |||||
Power supply Zero point | ±0.05%FS/power fluctuation ±10% | ||||
Sensitivity : ±0.05%/power fluctuation ±10% | |||||
hstand voltage | 1000VAC for 1 minute between measuring bridge and chassis | ||||
1000VAC for 1 minute between AC power supply and chassis | |||||
Output voltage indication
| 4 1/2 -digit(7-segment LED) indicator | ||||
11-segment LED bar graph meter | |||||
Overinput indication | Output voltage indication flickers(41/2-digit digitalindication only) | ||||
Checking function | Checking function | ||||
Checking function | Locks all keys other than POWER switch | ||||
(setting on digital CAL and VOLTAGE OUTswitches can be changed) | |||||
Remote function | Enables remote execution of balance adjustment(BAL),reference equivalent strain output(CAL) and key lock | ||||
TEDS | Reads TEDS information and sets VOLTAGE OUTas rated output | ||||
Actual load calibration | Sets VOLTAGE as actual load input | ||||
Operating temperature/humidity range | -10 to 50℃,20 to 85%RH( no condensation) | ||||
Power supply | AC 115V: Type (AC104 to 126V) | ||||
AC200V: Type (AC180 to 220V) | |||||
AC230V: Type (AC207V) | |||||
10.5 to 15 V DC (Approx.0.6A/12VDC) | |||||
Weight | Approx.1.2kg |
AC power cable P-25 (with conversion adapter CM-39)
Output cable U-59,U-08
Spare fuses (Midget type 0.5A and 1A)
Miniature screwdriver, Instruction Manual
Bridge boxes DB/DBB
Housing cases YB-A
Noise filters F
Amplifier stand FA-1B
Extension cables N-81 to N-85