Categories

Manufacturers

Newsletter

http://dutapersada.co.id/568-thickbox_default/lutron-lcr-9184.jpg View full size

LUTRON LCR-9184

LCR Meter

Intelligent microprocessor circuit

Professional LCR Meter

More details

Call 022 7106162

Add Subtract

Features:

  • 19999/1999 counts dual LCD display
  • Auto LCR smart check and measurement.
  • Test range : (ex : F = 1 KHz)

        L : 200.00 uH to 2000.0 H
        C : 2000.0 pF to 2.000 mF
        R : 20.000 to 200.0 M

  • Series/Parallel modes are selectable.
  • DCR mode 200.00 to 200.0M
  • Five test frequency are available :

       100 Hz/120 Hz/1 KHz/10 KHz/100 KHz

  • Ls/Lp/Cs/Cp with D / Q / / ESR Parameter.
  • LCD Display with backlight structure.
  • Power : DC 9V battery or DC 9V adapter in.
  • RS232/USB computer interface.
  • Optional SMD test clips, SMDC-21.
  • Optional SMD tester, SMDA-22.
  • Optional USB cable, USB-01.
  • Optional data acquisition software, SW-E803.
  • Optional holster, HS-03.

 

GENERAL SPECIFICATIONS
Display:LCD size: 56.4 x 52.9 mm
LCD with green backlight (ON /OFF)
Test frequency:100 Hz/120 Hz/1 KHz/10 KHz/100 KHz
Function:L/C/R Function selector
Frequency selector
D/Q/0/ESR selector
Sorting mode selector
Backlight
Dissipation and Quality Factor:0.000 to 999
0 Measurement: ± 90°
Sorting tolerance mode:± 0.25%, ± 0.5%, ± 1%, ± 2%, ± 5%
± 10%, ± 20%, +80% -20%
Calibration:Open/Short calibration
Data Hold Freeze the display reading
Data output:RS 232/USB PC computer interface.
Power off:Auto shut off saves battery life or manual off by push button
Operating temperature:0°C to 50°C
Operating humidity:< than 85% RH
Power supply:006P DC 9V battery or equivalent. Alkaline or Heavy duty type
DC 9V adapter input (AC/DC power adapter is optional)
Power consumption:DC 35mA approx.
Dimensions:193 x 88 x 41 mm
Weight:420 gr. meter only

 

ELECTRICAL SPECIFICATIONS (23°C ±5°C)
RESISTANCE (DCR)
Range
Accuracy
Remark
20 Ohm ±(0.5%+5d)After Short CAL.
200 Ohm  
2 kOhm  
20 kOhm 
200 kOhm 
2 MOhm After Open CAL.
20 MOhm ±(1%+5d)After Open CAL.
200 MOhm ±(2%+5d)After Open CAL.

RESISTANCE (Rp/Rs)
Range
Accuracy
Accuracy
Remark
 
100 Hz/120 Hz
1000 Hz
 
20 Ohm ±(1%+5d)±(1%+5d)After Short CAL.
200 Ohm ±(0.5%+5d)±(0.5%+5d) 
2 kOhm  
20 kOhm 
200 kOhm 
2 MOhm ±(1%+5d)±(1%+5d)After Open CAL.
20 MOhm ±(1%+5d)±(2%+5d)After Open CAL.
200 MOhm ±(2%+5d)±(5%+5d)After Open CAL.

Range
Accuracy
Accuracy
Remark
 
10 kHz
100 kHz
 
20 Ohm ±(1%+5d)±(2%+5d)After Short CAL.
200 Ohm ±(0.5%+5d)±(0.5%+5d) 
2 kOhm  
20 kOhm 
200 kOhm 
2 MOhm ±(1%+5d)±(2%+5d)After Open CAL.
20 MOhm ±(2%+5d)-------------After Open CAL.

CAPACITANCE (Cp/Cs): D < 0.1
Range
Accuracy
Accuracy
Remark
 
100 Hz/120 Hz
1000 Hz
 
20 pF±(2%+5d)±(1%+5d)After Open CAL.
200 pF±(1%+5d)±(1%+5d)After Open CAL.
2000 pF±(0.8%+5d)±(0.8%+5d)After Open CAL.
20 nF±(0.5%+5d)±(0.5%+5d) 
200 nF 
2000 nF 
20 uF 
200 uFAfter Short CAL.
2000 uF±(1%+5d)±(1%+5d)After Short CAL.
20 mF±(2%+5d)---------------After Short CAL.

Range
Accuracy
Accuracy
Remark
 
10 kHz
100 kHz
 
20 pF±(1%+5d)±(1%+5d)After Open CAL.
200 pF±(0.5%+5d)±(0.5%+5d)After Open CAL.
2000 pFAfter Open CAL.
20 nF 
200 nF 
2000 nF 
20 uF±(0.8%+5d)±(0.8%+5d) 
200 uF±(1%+5d)---------------After Short CAL.

INDUCTANCE (Lp/Ls): D < 0.1
Range
Accuracy
Accuracy
Remark
 
100 Hz/120 Hz
1000 Hz
 
20 uH±(1%+5d)±(1%+5d)After Short CAL.
200 uHAfter Short CAL.
2000 uH±(0.8%+5d)±(0.8%+5d) 
20 mH±(0.5%+5d)±(0.5%+5d) 
200 mH 
2000 mH 
20 H 
200 H±(0.8%+5d) 
2000 H±(1%+5d)-------------------After Open CAL.

Range
Accuracy
Accuracy
Remark
 
10 kHz
100 kHz
 
20 uH±(1%+5d)±(1%+5d)After Short CAL.
200 uH±(0.8%+5d)±(0.8%+5d)After Short CAL.
2000 uH±(0.5%+5d)±(0.5%+5d) 
20 mH 
200 mH--------------- 
2000 mH--------------- 