UCAM-500B
Data Loggers
Fast Data Logger
KYOWA UCAM-500B
Can Measure Quasi-Dynamic Phenomena
Call 022 7106162
Data Loggers
Fast Data Logger
KYOWA UCAM-500B
Can Measure Quasi-Dynamic Phenomena
Call 022 7106162
Maximum 1000 measuring channels.Flexibly coping with small to large scale measurement
The UCAM-500B is a fast data logger system which can simultaneously sample variables at multiple points at a maximum rate of 50 times per second. The system is composed of fast data logger scanner(s) USB-500A, the fast data logger controller UCAM-500B which records measured data at high speed, and a PC in which the control software UCS-60B is installed for setting, controlling and data collection. The scanner and controller are black boxes having no operating switches and controls.Scanning speeds include 1 time per second for 1000 channels and 50 times per second for 100 channels, making the system applicable for measurement of static to quasi-dynamic phenomena. In addition, the strain unit, voltage unit and temperature unit can be mounted to the scanner, enabling the system to connect to strain gages, strain gage transducers, potentiometer sensors, voltage-output instruments and thermocouples. The scanner provides a maximum 50 channels and the controller can connect to a maximum 20 scanners, enabling the system to measure variables at a maximum 1000 points.Signals from sensors are digitized by A-D converters in the scanner, and then transferred to the controller via the dedicated interface. The controller stores the data in a built-in semiconductor memory and whenever commanded from the PC, the controller transfers the data to the PC. Since control commands of the controller are disclosed, users can create their original software to configure the optimum system for a specific measuring purpose.
Note : For LAN connecion, use a LAN hub and straight cable.
■Fast Data Logger Controller UCAM-500B | |||||||||||||||||||||||||
Number of Connectable Scanners (USB-500A) | 1 to 20 (maximum 1000 channels) | ||||||||||||||||||||||||
Functions | Receives data from scanner | ||||||||||||||||||||||||
and stores it in memory. | |||||||||||||||||||||||||
Transfers data to PC. | |||||||||||||||||||||||||
Measuring Modes | Real-time | ||||||||||||||||||||||||
interval | |||||||||||||||||||||||||
trigger | |||||||||||||||||||||||||
monitor | |||||||||||||||||||||||||
Measurement Functions | initial, original, measure | ||||||||||||||||||||||||
Initial Value Memory Range | Same as measuring range of scanner | ||||||||||||||||||||||||
Conversion to Physical Quantities into Engineering Units | Through multiplication of measured values (strain, voltage,potentiometer signals) by preset coefficients. (For details, refer to specifications of the control software.) | ||||||||||||||||||||||||
Memory | 64 MB (backed for approx. 4 years at 20℃) Measured data is stored in this semiconductor memory but parameters of calculation channels cannot be stored. | ||||||||||||||||||||||||
Maximm Number of Storing Times
| |||||||||||||||||||||||||
nterfaces | Dedicated interface between controller and scanner | ||||||||||||||||||||||||
Total extensible length up to 185 m | |||||||||||||||||||||||||
LAN interface between controller and PC | |||||||||||||||||||||||||
(10BASE-T/100BASE-TX) | |||||||||||||||||||||||||
Real-time Clock | Year, month, day, hour, minute, second | ||||||||||||||||||||||||
(used for interval measurement, etc.; backed for approx. 8 years at 20℃) | |||||||||||||||||||||||||
Operating Temperature/Humidity Range | 0 to 40℃, 20 to 85% | ||||||||||||||||||||||||
RH (noncondensing) | |||||||||||||||||||||||||
Power Supply | AC85 to 264V, 50/60 Hz, approx. 50 VA | ||||||||||||||||||||||||
Dimensions | 426(W) x 88(H) x 300(D) mm (excluding protrusions) | ||||||||||||||||||||||||
Weight | Approx. 6 kg |
Control software UCS-60B (CD-R)
AC power cable P-18 (with conversion adapter CM-33)
Synchronous cable US-50A 2 m long
T-type BNC connector, BNC terminator, Grounding conductor,
Spare fuse (in fuse holder), Instruction manual
USB-500A |
Applicable Sensors and Measuring Units
Measuring Unit Applicable Sensors | Strain UnitUSS-51A | Voltage UnitUSV-51A | Thermocouple UnitUST-51A | ||
---|---|---|---|---|---|
Strain gage Strain gage transducer | 1-gagemethod | 120Ω | ● | ||
350Ω | ● | ||||
1-gagemethod (true-dummy) | 120Ω | ● | |||
350Ω | ● | ||||
2-gage method 120 to 1000Ω | Active-dummy | ● | |||
Active-active | ● | ||||
4-gage method 120 to 1000Ω | Opposite side active | ● | |||
Full-bridge | ● | ||||
Potentiometer sensor | 1 to10kΩ | ● | |||
Voltage-output sensor | ±20.0V | ● | |||
Thermocouple
| K(CA) | ● | |||
T(CC) | ● | ||||
E(CRC) | ● | ||||
J(IC) | ● | ||||
R | ● |
Number of Measuring Channels | 50 | ||||||||||||||||||
(with 5 measuring units mounted, 10 channels per unit) | |||||||||||||||||||
Data Update
To update data at 10 times/sec, 20 times/sec or 50 times/sec, scanners should be connected with each other using synchronous cable US-50A. | |||||||||||||||||||
Frequency Response Range | DC to 7.8 Hz (deviation 0.5 dB/ 3.5 dB) |
Interface | Dedicated interface between controller and scanner and between each scanner |
Dedicated interface cable 2 m long (provided standard foreach scanner), | |
total extensible length up to 185 m | |
Operating Temperature/Humidity Range | 0 to 40℃, |
20 to 85% RH (noncondensing) | |
Power Supply | AC85 to 264V, 50/60 Hz, approx. 50 VA |
Dimensions | 426(W) x 133(H) x 300(D) mm (excluding protrusions) |
Weight | Approx. 6.5 kg (with 5 USS-51A strain units mounted) |
AC power cable P-18 (1.8 m long with conversion adapter CM-33)
Dedicated interface cable 2 m long, T-type BNC connector,
Grounding conductor, Spare fuse (in fuse holder)
USS-51A | |
Number of Measuring Channels | 10 |
Applicable Sensors | Strain gages, strain gage transducers,potentiometer sensors |
Bridge Excitation | 2 VDC, constant voltage (regularly applied) |
Potentiometer Supply | 2 VDC, constant voltge (regularly applied) |
Gage Factor | 2.00 fixed (conversion to engineering unit function enables correction with 2.00/Ks) |
Signal | Range Mode | Measuring Range | Resolution | Accuracy |
---|---|---|---|---|
Strain | L | 0 to ±19000μm/m | 1 μm/m | ±0.05%FS |
H | 0 to ±200000μm/m | 10 μm/m | ||
Potentiometer Sensor | 0 to ±50% | 0.01% | ±0.1%FS |
With static (DC) signal input
Note : The stated measuring ranges are for INITIAL or ORIGINAL measurement mode. In MEASURE mode, the range is the result obtained by subtracting the pre-measured initial value from the original value.
●USS-51A M1 for transducers with NDIS connector
●USS-51A M6 with one-touch clamp style terminal board
USV-51A | |
Number of Measuring Channels | 10 |
Applicable Sensors | DC voltage, voltage-output sensor |
Measuring Range | Resolution | Accuracy | Signal Source Resistance |
---|---|---|---|
Measuring Range | 1mV | ±0.05%FS | 50 Ω or less |
With static (DC) signal input
UST-51A | |
Number of Measuring Channels | 10 |
Applicable Sensors | Thermocouples |
Type | Range Mode | Measuring Range | Resolution | Accuracy |
---|---|---|---|---|
K | L | -200.0 to 437.0℃ | 0.1℃ | ±0.8℃ |
H | -200.0 to 1200.0℃ | 0.1℃ | ±2.8℃ | |
T | ― | -200.0 to 350.0℃ | 0.1℃ | ±0.7℃ |
E | L | -200.0 to 260.0℃ | 0.1℃ | ±0.5℃ |
H | -200.0 to 800.0℃ | 0.1℃ | ±1.7℃ | |
J | L | 0 to 330.0℃ | 0.1℃ | ±0.3℃ |
H | 0 to 750.0℃ | 0.1℃ | ±1.9℃ | |
R | ― | 0 to 1600.0℃ | 0.2℃ | ±2.2℃ |
With static (DC) signal input
Note: The stated accuracies do not include the internal reference junction accuracy. The internal reference junction compensator accuracy is ±0.5℃ (with input terminal temperature balanced at 25℃ ±10℃).
Reference junction compensator is switchable between internal and external.
For thermocouple resistance 300Ω or less (K type), contact us.
UT-50A | |
This dustproof cover protects the input terminals of the measuring unit. | |
It is included in standard accessories to the thermocouple unit UST-51A. |
JIS rack-mounting bracket UR-50A for UCAM-500B |
EIA rack-mounting bracket UR-51A for UCAM-500B |
JIS rack-mounting bracket UR-52A for USB-500A |
EIA rack-mounting bracket UR-53A for USB-500A |
Rack/drawer-mounting bracket UR-54A for USB-500A |
US-50A |
Required for data update at 10 times per second or more with 2 to 4 scanners. One each synchronous cable is provided standard for each scanner. 1 synchronous cable is required to operate 3 scanners in synchronizaton, and 2 synchronous cables are required to operate 4 scanners in synchronization. |
U-17~20 |
UD-50A |
To cover the portion of USB-500A to which no measuring unit is mounted. |
UPT-300B |
Use this isolation transformer to obtain good measurement resultswhere adverse power environment may cause noise, etc. |
JT-1A |
Mounted to the input terminal of the measuring unit, the JT-1A enables quick fitting of the input leadwire cable. It will be used for one each leadwire cable. (10 pieces per pack) |
UCS-60B |
Standard accessory to the UCAM-500B. For details,refer to here |